Connection diagram for lexium 17s – Schneider Electric Lexium 17S Series User Manual

Page 57

Advertising
background image

45

Connection diagram for Lexium 17S

Reference Safety Instructions
and Use As Directed!

Sine-Cosine

Encoder

Resolver

M

thermal control
included

15

thermal control
included

8

6

5

4

3

Resolver

V

W

P

U2

V2

W

PE

B+

B-

2
1

high
resolution
single /
multiturn

Regeneration

resistor

F

B1

F

B2

PE-connection (protective earth)

earth connection (panel)

shield connection via plug

COM1/COM2

PC

X6

X5

X3

X1

X2

X9

U

Brake-

Brake+

Analog 1 in -

Analog Com

Analog 2 in +

Analog 2 in -

Reserved

I/O Com

Input 3

Analog 1 in +

Input 4

Input 1

Input 2

Enable

Output 1

Output 2

Fault RA

Fault RB

ROD

SSI

Ma./SI.

3

encoder-
evaluation,

slave/master
amplifier

Safety

circuit

Digital2

Digital1

+24V referenced
to 0V/GND

I/O-GND

GND

+ +/-10V speed
setpoint2
referenced to GND

GND

GND

+ +/-10V speed
setpoint1
referenced to GND

4

5

1

6

7

8

10

9

18

13

14

11

12

15

16

17

2

3

Analog Com

Reserved

X8

2
1

Remove jumper if external
regen resistor is connected

3
4

+R

Bint

-R

B

n.c.

+R

Bext

PE

L1

L2

L3

X0A

1

2

3

4

F

N

F

N

F

N

Master
contactor

PE L1 L2 L3

supply unit

24V DC

1

2

3

4

+24 Vdc

X4

24 Vdc Com

F

H

1

2

3

4

1

2

3

4

DC+

DC+

DC-

DC-

X7

X0B

L1 L2 L3 PE

shielding if cable
is longer than 20cm

shield connection at the front panel

to other amplifiers

Advertising