Turning a downstream key on and off, Timing of the gpi signal – Sony DFS-700 User Manual

Page 127

Advertising
background image

Chapter 5 Control From Editing

Control Units

Chapter 5 Control From Editing Control Units

5-13

Timing of the GPI signal

The timing of the GPI signal from the editing control unit is as follows.

Timing of GPI signal in A/B roll editing

Turning a Downstream Key On and Off

If in page 1 of the setup menu you have set F3(PORTS) to “PVE-500” or
“GPI” then you can turn a downstream key on and off using a GPI signal
input to the T2 connector on the DFS-700/700P.
As shown below, the downstream key is turned alternately on and off at
the falling edge of the GPI signal.

Turning a downstream key on and off — GPI signal timing

VCRs start

IN point

Effect start point

OUT point

VCRs stop

Player A

Player B

Recorder

GPI signal

3 frames

PGM OUT
signal

Background bus image

Foreground bus
image

Preroll

Execution of
effect (transition)

Postroll

A-roll period

B-roll period

GPI signal

3 frames

3 frames

DSK ON

DSK OFF

Advertising