Displaying parameter values

The numerical values of the parameters appear in the menu.

Numerical parameter values

a) 600 corresponds to the full width of the screen.
b) 300 corresponds to the full height of the screen.
c) 100 corresponds to 360 degrees.
d) For SPHERE, the Angle and the Radius parameter do not function.

Resetting the parameters to their initial values

• To reset all of the parameters, hold down the INITIAL button, and press

the PATTERN ADJ button.
The initial values of the parameters are for an unmodified image
occupying the whole screen.

• To reset all of the parameters on a particular page, hold down the

INITIAL button, and press the PAGE button.

• To reset a particular parameter only, press the corresponding function

button while holding down the INITIAL button.

User Program Effects

Parameter

Function

Value range

Default

Loc-X

Movement along x-axis

–800 to +800

a)

0

Loc-Y

Movement along y-axis

–600 to +600

b)

0

Loc-Z

Magnification

0 to 200

100

KfDur

Key frame duration

1 to 100

50

Rot-X

Rotation about the x-axis

–400 to +400

c)

0

Rot-Y

Rotation about the y-axis

–400 to +400

c)

0

Rot-Z

Rotation about the z-axis

–400 to +400

c)

0

Pers

Perspective

0 to 400

200

Angle

Direction of folding

–100 to +100

c)

20

Offset

Degree of modification

0 to 200

0

Rot-Z

Rotation about the z-axis

–400 to +400

c)

0

Radius

Radius

0 to 100

0

FORM

Type of modification

TURN, ROLL, SPHERE

d)

TURN