Installation Overview

Innova-Flo™ meter installations are simple and straightforward. Both the Se-
ries 220 In-Line and Series 221 Insertion type flow meter installations are
covered in this chapter. After reviewing the installation requirements given
below, see page 2-3 for Series 220 installation instructions. See page 2-6 for
Series 221 installation instructions. Wiring instructions begin on page 2-19.

Flow Meter Installation Requirements

Before installing the flow meter, verify the installation site allows for these
considerations:

Warning!

Consult the flow meter name-

plate for specific flow meter

approvals before any hazard-

ous location installation.

1. Line pressure and temperature will not exceed the flow meter

rating.


2. The location meets the required minimum number of pipe di-

ameters upstream and downstream of the sensor head as illus-
trated Figure 2-1.


3. Safe and convenient access with adequate overhead clearance

for maintenance purposes.


4. Verify that the cable entry into the instrument meets the specific

standard required for hazardous area installations.

5.

For remote installations, verify the supplied cable length is suf-
ficient to connect the flow meter sensor to the remote electron-
ics.

Also, before installation check your flow system for anomalies such as:

• leaks
• valves or restrictions in the flow path that could create disturbances in

the flow profile that might cause unexpected flow rate indications

IM-22