A-2 im-22 – Sierra INNOVA-FLO 220 User Manual

Page 61

Advertising
background image

Appendix A Specifications

Series 220/221 Instruction Manual

A-2

IM-22

Water Minimum and Maximum Flow Rates

½-inch

¾-inch

1-inch

1.5-inch

2-inch 3-inch 4-inch 6-inch 8-inch

gpm 1

22

1.3

40

2.2

67

5.5

166

9.2

276

21

618

36

1076

81

2437

142

4270

m

3

/hr .23

5

.3

9.1

0.5

15

1.3

38

2.1

63

4.7

140

8.1

244

18

554

32

970



Linear Range

Smart electronics corrects for lower flow down to a Reynolds num-
ber of 5,000. The Reynolds number is calculated using the fluid
density and viscosity entered into the memory. Rangeability de-
pends on the fluid, process conditions and pipe size. Consult factory
for your application. Velocity rangeability under ideal conditions is as
follows:


Liquids 30:1

1 foot per second velocity minimum

30 feet per second velocity maximum

Gases 30:1

10 feet per second velocity minimum

300 feet per second velocity maximum


Process Fluid Pressure

220 Pressure Ratings

Process

Connection

Material Rating

Flanged

316L SS, A105 Carbon Steel, C276 Hastelloy

150, 300, 600 lb

Wafer

316L SS, A105 Carbon Steel, C276 Hastelloy

600 lb

221 Pressure Ratings

Probe Seal

Process

Connection

Material Rating Ordering

Code

Compression
Fitting

2-inch MNPT

316L SS

ANSI 600 lb

CM

2-inch 150 lb flange

316L SS

ANSI 150 lb

CF

2-inch 300 lb flange

316L SS

ANSI 300 lb

CG

2-inch 600 lb flange

316L SS

ANSI 600 lb

CH

Packing Gland

2-inch MNPT

316L SS

50 psig

PM

2-inch 150 lb flange

316L SS

50 psig

PF

2-inch 300 lb flange

316L SS

50 psig

PG

Packing Gland with
Removable Retractor

2-inch MNPT

316L SS

ANSI 300 lb

PM, RR

2-inch 150 lb flange

316L SS

ANSI 150 lb

PF, RR

2-inch 300 lb flange

316L SS

ANSI 300 lb

PG, RR

Packing Gland with
Permanent Retractor

2-inch MNPT

316L SS

ANSI 600 lb

PMR

2-inch 150 lb flange

316L SS

ANSI 150 lb

PFR

2-inch 300 lb flange

316L SS

ANSI 300 lb

PGR

2-inch 600 lb flange

316L SS

ANSI 600 lb

PHR

Process Fluid and
Ambient Temperature

Process Fluid:

Standard temperature sensor: –40° to 400° F (–40° to 205° C).

Medium temperature sensor: 250° to 500° F (120° to 260° C).

High temperature sensor: 250° to 750° F (120° to 400° C).


Ambient:

Operating: –5° to 140° F (–20° to 60° C).

Storage: –40° to 150° F (–40° to 65° C).

0-98% relative humidity, non-condensing conditions.

Advertising