Chapter 3 Operation

Display Menu


Password

ENTER

Use
keys to access menus

Display

Menu

Cycle Time(sec)

0

ENTER

Run Mode

Number of Digits

2

Display VFlow?

YES or NO

Display MFlow?

YES or NO

If Cycle Time is set to zero, manual advance is required

Used to set the number of digits displayed after
decimal point

For each parameter:
Select Yes to view parameter in Run Mode
Select No to hide parameter in Run Mode

Display TC(sec)

1

TC = Display Time Constant, used to smooth display

Display Total?

YES or NO


Use the Display Menu to set the cycle time for automatic screen sequencing used in the Run Mode,
change the precision of displayed values, smooth the values or enable or disable each item displayed
in the Run Mode screens.

Example for Changing a Run Mode Display Item

The following shows how to remove the mass flow screen from the Run Mode screens. Note: all outputs are
disabled while using the Setup Menus.
1. Use ÕÖ keys to move to the Display Menu.
2. Press Ø key until Display MFlow? appears.
3. Press

ENTER

to select.

4. Press Ø key until N appears. Press

ENTER

to select.

5. Press EXIT and then

ENTER

to save changes and return to the Run Mode.


IM-22