Chapter 8

Removing and Replacing Components

93

If the server is already in use, see “To Change Components In a Sun Fire V100
Server That Is In Use” on page 88.

1. Place the unit on an ESD surface and attach an antistatic wrist strap (see

FIGURE 8-2

).

2. Remove the server’s top cover (see “To Remove the Top Cover” on page 89).

3. Remove the metal placeholder if your server has one (if it was configured with a

single hard disk drive, the second hard disk drive slot will have the placeholder
installed).

FIGURE 8-7

Removing the HDD Placeholder

4. Insert and align the new hard disk drive (see

FIGURE 8-8

).

a. Position HDD and slide onto the clips on the base of the server.

b. Press the handle into the two clips on the base of the server.