Operating power statistics, Environmental compliance information – Sun Microsystems Sun Fire V100 User Manual

Page 135

Advertising
background image

Appendix A

Physical and Environmental Specifications

117

Environmental Compliance Information

Electromagnetic compatibility

Immunity: The server conforms to EN55024.

Emissions: The server conforms to EN55022 Class A and FCC Class A.

Safety
The system conforms to UL 1950 (3rd edition), EN60950

Operating Power Statistics

*

The in-rush current decays to the normal operating current in less than 200 msecs.

Caution –

The power supply continues to regulate all outputs for at least 17 ms

after AC power is removed.

Note –

Logic ground and chassis ground are connected internally.

TABLE A-2

Operating Power Statistics

Maximum operating current

1.3A @ 100 VAC

Typical operating current

See “Calculating Power Consumption” on
page 118

Maximum in-rush
current (cold start)*

40A peak at 115V

25˚C

Maximum in-rush
current (warm start, or upon a restart 20 to
200 msecs after power has been removed

*

)

100A peak at 115V

25˚C

Operating input voltage range

90 to 264 Vrms

Voltage frequency range

47 to 63 Hz

Power factor

0.9 to 0.99

Maximum volt-ampere rating

130 VA

BTU/hr

500 MHz processor: 148 (min), 280 (max).

Advertising