Ide controller failure, Jumper settings – Sun Microsystems Sun Fire V100 User Manual

Page 125

Advertising
background image

Chapter 10

Troubleshooting

107

IDE Controller Failure

The probe-IDE diagnostic transmits an inquiry command to internal and external
IDE devices connected to the system’s on-board IDE interface. If the IDE device is
connected and active, the target address, unit number, device type, and
manufacturer name are displayed. Initialize the probe-IDE diagnostic by typing the

probe-ide

command at the

ok

prompt. The following code example shows the

probe-IDE diagnostic:

Jumper Settings

The default settings for the jumpers are shown below. Do not change these settings.

ok probe-ide

Device 0 ( Primary Master )

ATA Model: ST34342A

Device 1 ( Primary Slave )

ATA Model: ST34342A

ok

Jumper Name

Jumper Setting

JP1

1-2

JP3

Not used.

JP7

1-2, 5-6.

JP8

Not used.

JP9

1-2

JP13

Jumper not fitted.

JP14

Jumper not fitted.

JP15

1-2

JP16

Jumper not fitted.

JP18

Jumper not fitted.

JP19

Jumper not fitted.