Connecting the cables – Sun Microsystems Sun Fire V100 User Manual

Page 35

Advertising
background image

Chapter 2

Installing the Sun Fire V100 Server Into a Rack

17

1 RU (part number: 330-2610-01)

2 RU (part number: 330-2611-01)

3 RU (part number: 330-2613-01)

4 RU (part number: 330-2614-01)

5 RU (part number: 330-2615-01)

Position your racks so that the warm air exhaust from one rack does not flow
directly into the cool air intake area for another.

If space is limited at the back of your Sun StorEdge 72-inch rack, install a
redundant fan tray (part number: X9819A) into the top of the rack. This pulls air
up through the top of the rack to prevent the build-up of heat behind it.

Connecting the Cables

The following section describes the positions of the ports and sockets for the
corresponding cables, and the correct procedure for connecting the cables.

The server’s ports are arranged and numbered as in

FIGURE 2-10

.

FIGURE 2-10

The Server’s Back Panel

To Connect the Cables to the Server

1. Connect the power cord.

On/Standby

System configuration
card reader

B Serial

Ethernet 1

USB 0

Power

A/LOM

USB 1

Fan

Ethernet 0