Sun Microsystems Sun Fire V100 User Manual

Page 42

Advertising
background image

24

Sun Fire V100 User’s Guide • December 2001

■

RJ-45 to RJ-45 patch cable

Both are supplied with the Sun Fire V100 server.

▼

To Connect to the Server Using a Sun
Workstation

1. Connect to the server using the RJ-45 patch cable and DB-25 adapter as described

in “To Use the DB-25 Adapter” on page 23.

2. From a terminal session, type:

The

tip

command above is for a console that is using its ttya serial port. If you later

configure your console to use ttyb, type the following to set up a

tip

session:

For information about dedicating the console to Serial B, see “Managing the Sun Fire
V100 Server From the lom> Prompt” on page 43.

For information about how to power on and configure the server, go to “Powering
On and Configuring the Server” on page 34.

▼

To Connect to the Server Using an ASCII
Terminal

1. Set up a connection between the terminal and the Sun Fire V100 server.

See “To Use the DB-25 Adapter” on page 23.

2. For the General terminal settings, refer to the terminal operating manual.

# tip /dev/term/a -9600

# tip /dev/term/b -9600