B.4 RS-232C Protocol

B-7

B.4

RS-232C Protocol

B.4.1

Parameters of the RS-232C Protocol

A protocol is a set of rules followed by various devices to send or receive data. The
parameters of the RS-232C protocol are stored in the battery-powered memory of the
printer. You can verify these parameters on the status printout as marked by the following
identifications:

H1: Baud rate

H2: Number of data bits

H3: Number of stop bits

H4: Parity

H5: Protocol logic

H6: Buffer-nearly-full threshold

H7: Buffer nearly-empty threshold

H8: Received data buffer size

The parameters can be changed from the printer operator panel. To change the value for the
serial interface parameters, see

Chapter 3 Using the Operator Panel, section 3.5.2

Changing Serial Interface Parameters on page 3-35

.

This following section outlines the parameters and their values you can select on the
operator panel:

H1: Baud rate

The factory setting is 96 (9600 baud).

H2: Number of data bits

7 or 8. The factory setting is 8.

H3: Number of stop bits

1 or 2. The factory setting is 1.

Parameter value

Baud rate

12

1200

24

2400

48

4800

96

9600

19

19200

38

38400

57

57600

11