Fireplace and framing specifications, Figure 13 – Lennox Hearth ELITE ELDV-40NM User Manual

Page 10

Advertising
background image

10

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

FIREPLACE AND FRAMING SPECIFICATIONS

Vent Size

Co-axial DV

Vent Size

4-1/2" Inner

7-1/2" Outer

Vertical Venting Through the Ceiling:
Frame ceiling opening
- Use a plumb line from the ceiling above the appliance to
locate center of the vertical run. Cut and/or frame an opening, 10-1/2" x 10-1/2" (267
mm x 267 mm) inside dimensions, about this center mark (see Figure 18).

Notes

Diagrams, illustrations and photo-

graphs are not to scale – consult

installation instructions. Product

designs, materials, dimensions,

specifications, colors and prices are

subject to change or discontinuance

without notice.

Input (BTU/HR) - MV & Electronic

Natural & Propane Gas

Models

Input Rate (BTU / HR)

ELDV35N

27,000

ELDV35P

26,000

ELDV40N

29,000

ELDV40P

27,000

ELDV45N

30,000

ELDV45P

28,000

Viewable Glass Size

35" Model

29-1/4" Wide

20-1/4" High

40" Model

34-1/4" Wide

25-1/4" High

45" Model

39-1/4" Wide

25-1/4" High

Figure 13

Framing

A

B

D

7

(178)

5-1/8

12-1/8

(308)

10-1/2

(

267

)

C

(130)

A

1/2

Framing Dimensions

Model No.

A

B

C

D

ELDV35

in.

35-9/16

40-5/16

21-7/16

56-1/2

mm

903

1024

545

1435

ELDV40

in.

40-9/16

40-5/16

21-7/16

56-1/2

mm

1030

1024

545

1435

ELDV45

in.

45-9/16

40-5/16

21-7/16

56-1/2

mm

1157

1024

545

1435

Vent Framing - Top Vent
With One 90° Elbow

C is the required framing depth dimension when the fin-
ish material (drywall) thickness is 1/2 in. (13mm)

Inches (millimeters)

Framing should be

constructed of 2x4 or

larger lumber

Efficiencies %

Models

Natural Gas

Propane

P4

Steady

State

AFUE

P4

Steady

State

AFUE

ELDV-35

47

65

63

47

68

66

EDLV-40

48

68

66

53

66

64

ELDV-45

49

66

64

47

67

65

l

e

d

o

M

.

o

N

A

B

C

D

E

F

G

H

5

3

V

D

L

E

.

n

i

8

/

1

0

4

8

/

1

7

3

8

/

5

5

2

8

/

1

9

2

8

/

1

5

3

2

/

1

1

2

4

/

3

0

1

2

/

1

2

3

m

m

1

9

0

1

3

4

9

1

5

6

0

4

7

2

9

8

6

4

5

3

7

2

5

2

8

0

4

V

D

L

E

.

n

i

8

/

1

0

4

8

/

1

7

3

8

/

5

5

2

8

/

1

4

3

8

/

1

0

4

2

/

1

6

2

4

/

3

3

1

2

/

1

2

3

m

m

1

9

0

1

3

4

9

1

5

6

7

6

8

9

1

0

1

5

7

6

7

3

3

5

2

8

5

4

V

D

L

E

.

n

i

8

/

1

0

4

8

/

1

7

3

8

/

5

5

2

8

/

1

9

3

8

/

1

5

4

2

/

1

1

3

4

/

3

5

1

2

/

1

2

3

m

m

1

9

0

1

3

4

9

1

5

6

4

9

9

6

4

1

1

2

0

8

1

0

4

5

2

8

TOP VIEW

FLUE OUTLET

- 41/2 (114)

COMBUSTION AIR

- 71/2 (190)

F

G

10-1/2

(267)

FRONT VIEW

E

A

B

H

7-5/8

(194)

C

D

ELECTRICAL

INLET

20-15/16

(532)

1(25.4)

RIGHT SIDE VIEW

EYEBROW HOOD

(OPTIONAL)

2-1/4

(57)

6-1/2 (165)

GAS INLET

(LEFT SIDE ONLY)

NOTE: - The gas is to be stubbed in from the left side ONLY.

Advertising