Lennox Hearth ELITE ELDV-40NM User Manual

Page 19

Advertising
background image

19

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

J. Assemble vent run to exterior wall - If not

previously measured, locate the center of the

vent at the exterior wall. Prepare an opening as

described in Step B and Figure 29. Assemble

the vent system to point where the terminus of

the last section is located relative to the exterior

surface to which the termination is to be attached

as shown in Figure 30 and Table 9.

If the terminus of the last section is not within

this distance, use the telescopic vent section

SV4.5LA, as the last vent section. For wall

thicknesses greater than that shown in Figure

30, refer to Table 9 on Page 20. This Table lists

the additional venting components needed (in

addition to the termination and adaptor) for a

particular range of wall thicknesses.

K. Attach termination adaptor - Attach the

adaptor (SV4.5RCH - provided with the termi-

nation) to the vent section or telescoping vent

section), elbow or appliance collar as shown in

Figure 29 in the same manner as any SV4.5

vent component (refer to Step E).

L. Install Firestop/Spacer at exterior wall -

When using the termination, install SV4.5HF

(Secure Vent™), SF4.5HF (Secure Flex™)

Firestop/Spacer over the opening at the exterior

side of the framing, long side up, with the 3

inch spacer clearance at the top as shown in

Figure 29, and nail into place.

(The Firestop/Spacer may also be installed over

the opening at the interior side of framing).

M. Install the Termination (SV4.5HT-2)

For the last step, from outside the exterior

wall, slide the collars of the termination onto

the adaptor (the outer inside the outer and the

inner outside the inner) until the termination

seats against the exterior wall surface to which

it will be attached. Orient the housing of the

termination with the arrow pointed upwards.

Secure the termination to the exterior wall. The

horizontal termination must not be recessed

into the exterior wall or siding by more than

the 1-1/4" (32 mm) as shown in Figure 30.

IMPORTANT: The vent termination is hot

while in operation and for a period of

time following the use of the fireplace.

To prevent contact with hot surfaces,

we recommend the use of a Termina-

tion Guard. See Page 36. This can be

purchased at your local dealer.

Horizontal terminations have been designed to perform in a wide range of weather condi-

tions. Our terminations meet or exceed industry standards.

When selecting the locations of your horizontal terminations, do not place the termina-

tion where water from eaves and adjoining rooflines may create a heavy flow of cascad-

ing water onto the termination cap. If the cap must be placed where the possibility of

cascading water exists, it is the responsibility of the builder to direct the water away

from the termination cap by using gutters or other means.

Take care to carefully follow the installation instructions for the termination, including

the use of silicone caulking where required.

Figure 30

Figure 29 -

INSTALLING HORIZONTAL TERMINATION

Siding

Stucco

1-1/4" Maximum Recess of

the Square Termination into

Exterior Finishing Material

Exterior Surface of

Framing

6 in. to 9-1/4 in.

(152 to 235 mm)**

Exterior Surface of Siding

Interior Surface of

Finished Wall

Maximum wall thickness

9-1/4 in.(235 mm)**

SV4.5HT-2

Square Termination

Shown

Maximum Extent of

Vent Run Sections

Relative to Exterior

Surface of Framing

Last Vent Section. Use

T e l e s c o p i c V e n t

Section (SV4.5LA), If

Necessary

Adapter

SV4.5RCH

SV4.5HT-2

Square Termination

Shown

Venting Connection and Exterior Wall Recessing

of the Horizontal Termination

*Use silicone caulking to

seal the top and sides of

the termination, up to the

underlayment, stucco, or

masonry wall surface.

*Caulk

*Caulk

Firestop/Spacer (SV4.5HF) shown

on the exterior side of the wall. It

may also be installed on the

interior side.

Typical

Termination

Shown

7"

(178)

5-1/8"

(130 mm)

12-1/8"

(308 mm)

Note: Centerline of Vent Piping is

NOT the Same as the Centerline of

the Frame Opening.

6 to 48 inch Vent Section,

Telescopic vent section,

Elbow or Appliance Collar

See Figure 12 on page 9

for Min. Distance to Base

of Appliance.

Base of Appliance

3"

(76 mm)

1"

(25.4 mm)

Adapter

SV4.5RCH

10-1/2"

(267 mm)

**For thicknesses greater

than 9-1/4", see Table 9.

See Figure 13 on Page 10 for Min.

distance to Base of Appliance

Advertising