NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Push the vent component against the previous

section until it fully engages, then twist the

component clockwise running the dimples down

and along the incline channels until they seat at

the end of the channels. This seating position

is indicated by the alignment of the arrow and

dimple as shown in Figure 19.

D. Install firestop/spacer at ceiling - When

using Secure Vent™, use SV4.5VF firestop/

spacer at ceiling joists; when using Secure

Flex™, use SF4.5VF firestop/spacer. If there is

living space above the ceiling level, the firestop/

spacer must be installed on the bottom side of

the ceiling. If attic space is above the ceiling,

the firestop/spacer must be installed on the

top side of the joist.

Route the vent sections through the framed

opening and secure the firestop/spacer with

8d nails or other appropriate fasteners at

each corner. Remember to maintain 1" (25

mm) clearance to combustibles, framing

members, and attic or ceiling insulation

when running vertical chimney sections.

Attic insulation shield (H3907) may be used

to obtain the required clearances indicated

here. See installation accessories Pages 35

and 36. The gap between the vent pipe and

a vertical firestop can be sealed with non-

combustible caulking.

E. Support the vertical vent run sections -

Note - Proper venting support is very important.

The weight of the vent must not be supported

by the fireplace in any degree.

Support the vertical portion of the venting

system every 8 feet (2.4m) above the fireplace

vent outlet (see Figure 20 ).

Figure 19

Align the dimple (4 places) of the

upper vent section with the opening

of the locking incline channel on

the lower vent section or appliance

collar. Twist vent component

clockwise to engage and seal until

arrow and dimple align.

Dimple

Locking

Incline

Channel

Connected Vent

Sections

Arrow

Arrow

Appliance Collar or

Vent Section

Figure 18

10-1/2” Min.

(267mm)

10-1/2” Min.

(267mm)

Plumb

Bob

Roof

Framing

Ceiling

Framing

Vertical (Offset) Installation

Analyze the vent routing and determine the

quantities of vent sections and number of elbows

required. Refer to Vertical Vent Figures and

Tables on Pages 16 and 17 to select the type

of vertical installation desired. Vent sections

are available in net lengths of 4-1/2" (114 mm),

10-1/2" (267 mm), 22-1/2" (572 mm), 34-1/2"

(876 mm) and 46-1/2" (1181 mm). Refer to the

Vent Section Length Charts on Page 13 for an

aid in selecting length combinations. Elbows are

available in 90° and 45° configurations. Refer

to Figure 21 on Page 15 for the SV4.5E45 and

SV4.5E90 elbow dimensional specifications.

Where required, a telescopic vent section

(SV4.5LA) may be used to provide the installer

with an option in installing in tight and confined

spaces or where the vent run made up of fixed

length pieces develops a joint in a undesirable

location, or will not build up to the required

length. The SV4.5LA Telescopic Vent Section

has an effective length of from 1-1/2" (38 mm)

to 7-1/2" (191 mm). The SV4.5LA is fitted with

a locking inclined channel end (identical to a

normal vent section component) and a plain end

with 3 pilot holes. Slip the plain end over the

locking channel end of a standard SV4.5 vent

component the required distance and secure

with three screws.

Maintain a minimum 1" (25 mm) clearance to

combustible materials for all vertical elements.

Clearances for all horizontal elements are 3"

(76 mm) on top, 1" (25 mm) on sides and 1"

(25 mm) on the bottom.

A. Frame ceiling opening - Use a plumb line

from the ceiling above the appliance to locate

center of the vertical run. Cut and/or frame an

opening, 10-1/2" x 10-1/2" (267mm x 267mm)

inside dimensions, about this center mark

(Figure 18).

To attach a vent component to the appliance collar,

align the dimpled end over the collar, adjusting

the radial alignment until the four locking dimples

are aligned with the inlet of the four inclined chan-

nels on the collar (refer to Figure 19). Push the

vent component against the collar until it fully

engages, then twist the component clockwise,

running the dimples down and along the incline

channels until they seat at the end of the chan-

nels. The unitized design of the Secure Vent™

components will engage and seal both the inner

and outer pipe without the need for sealant or

screws. If desired, a #6 x 1/2" screw may be

used at the joint, but is not required as the pipe

will securely lock when twisted.

Note: An elbow may not be directly attached

to the appliance collar.

C. Attach vent components to each other - Other

vent sections may be added to the previously

installed section in accordance with the require-

ments of the vertical vent Figures and Tables.

To add another vent component to a length of

vent run, align the dimpled end over the inclined

channel end of the previously installed section,

adjusting the radial alignment until the four lock-

ing dimples are aligned with the inlets of the four

incline channels of the previous section.

B. Attach vent components to appliance -

Secure Vent SV4.5 direct-vent system compo-

nents are unitized concentric pipe components

featuring positive twist lock connections (see

Figure 19).

All of the appliances covered in this document

are fitted with collars having locking inclined

channels. The dimpled end of the vent com-

ponents fit over the appliance collar to create

the positive twist lock connection.

Blocking

Support Straps

(Plumber's tape)

8 feet (2.4 m)

Maximum

1/2 inch (12.7

mm) minimum

clearance to

combustibles

Figure 20