NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Step 3. INSTALL THE VENT SYSTEM

General Information

These instructions should be used as a

guideline and do not supersede local codes

in any way. Install venting according to local

codes, these instructions, the current National

Fuel Gas Code (ANSI-Z223.1) in the USA or

the current standards of CAN/CSA-B149.1

in Canada.

Ensure clearances are in accordance with

local installation codes and the requirements

of the gas supplier.

Dégagement conforme aux codes d'installation

locaux et aux exigences du foumisseunde

gaz.

Use only approved venting components.

See Approved Vent Components on

Page 2.

These fireplaces must be vented directly

to the outside.

Figure 16

Select Venting System - Horizontal or Vertical

With the appliance secured in framing, de-

termine vent routing and identify the exterior

termination location. The following sections

describe vertical (roof) and horizontal (exterior

wall) vent applications. Refer to the section

relating to your installation. A list of approved

venting components are shown on Pages 36

and 37.

Exhaust Vent

Fixed

Restrictor

Second

Restrictor

The vent system may not service multiple

appliances, and must never be connected to a

flue serving a solid fuel burning appliance. The

vent pipe is tested to be run inside an enclosed

wall (such as a chase). There is no requirement

for inspection openings in the enclosing wall at

any of the joints in the vent pipe.

Installation of Vent Restrictor

A vent restrictor may be needed with this

appliance. The restrictor is installed in the

appliance top flue outlet as shown in Figure

16, either before adding vent, from above, or

after installation of vent from below, within the

firebox. The restrictor is self securing through

a positive friction fit.

Determine the venting for the appliance. If the

vent run will include at least 8 feet of vertical

rise, then install the restrictor in the appliance

collar before connecting any vent (Refer to

Figure 16). Place the second restrictor inside

the fixed restrictor.

Note: The restrictor is included within the

firebox.