24

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Step 4. FIELD WIRING

B. Electronic Wiring (See Figure 37)

Note: The electronic appliance must be con-

nected to the main power supply.

1. Route a 3-wire 120Vac 60Hz 1ph power

supply to the appliance junction box.

2. Remove the electrical inlet cover plate from

the side of the unit by removing the plate's

securing screws (see Figure 13 on Page

10).

3. Remove the cover plate's knockout and

then feed the power supply wire through the

knockout opening and into the unit junction

box.

4. Connect the black power supply wire to the

lower outlet's red pigtail lead and the white

power supply wire to the common terminal

of the outlet as shown in Figures 37 & 38.

5. Connect the ground supply wire to the pig-

tail lead attached to outlet's green ground

screw.

6. Appliance-mounted ON/OFF burner control

switch (rocker switch) is factory installed

behind the bottom panel.

Optional wall-mounted switch, thermostat, or

one of the optional remote control kits may

also be used. The appliance mounted ON/OFF

switch needs to be relocated onto the optional

style view door, if used.

TP-TH

TP

TH

APPLIANCE- MOUNTED

ON/OFF SWITCH

(OPTIONAL)

BK/W(1)

BK/W(1)

WALL-MOUNTED ON/OFF SWITCH (OPTIONAL)

THERMOSTAT (OPTIONAL)

JUNCTION BOX

BLACK

W

GR

120 V AC

WALL MOUNTED CONFIGURATION FOR FAN SWITCH (OPTIONAL)

BK

R

WIRING DIAGRAM MILLIVOLT GAS VALVES

THERMOPILE

GAS VALVE

FAN

(OPTIONAL)

Figure 36

Figure 37

JUNCTION BOX

W

GR

BK

120 VAC

BK

R

TRANSFORMER 3V

INTERMITTENT ELECTRONIC WIRING DIAGRAM

BROWN

BROWN

BLACK

BATTERY BACK-UP

BLACK (SENSOR)

BLACK (IGNITER)

SPARK TO PILOT IGNITER

IGNITER MODULE

3V

RED

BK W GR

OPTIONAL BLOWER

SWITCH

FAN

(OPTIONAL)

PILOT

IN

OUT

VENT

LO

IN

ORANGE (THTP)

BLACK (TP)

GREEN (TH)

TO WALL

SWITCH OR

THERMOSTAT

Refer to Section A for millivolt appliances and

Section B for electronic appliances. The gas

valve is set in place and pre-wired at the factory

on both models.

A. Millivolt Wiring (See Figure 36)

1. Appliance-mounted ON/OFF burner control

switch (rocker switch) is factory installed

behind the bottom panel. Optional wall-

mounted switch, thermostat, or one of the

optional remote control kits may also be

used.

2. If wall-mounted ON/OFF control switch ther-

mostat is selected, mount it in a convenient

location on a wall near the fireplace.

3. Wire the control switch within the millivolt

control circuit using the 15 feet of 2 conductor

wire supplied with the unit.

Note: The supplied 15 feet of 2 conductor

wire has one end of each conductor con-

nected to the gas valve circuit and the other

end of each conductor placed loose inside

the bottom compartment.

4. If an optional control switch is installed,

turn the appliance-mounted ON/OFF burner

control switch to the OFF position.

CAUTION: Do Not connect the optional wall

switch to a 120V power supply.

CAUTION

Ground supply lead must be con-

nected to the wire attached to the

green ground screw located on the

outlet box. See

Figure 38

. Failure to

do so will result in a potential safety

hazard. The appliance must be

electrically grounded in accordance

with local codes or, in the absence of

local codes, the National Electrical

Code, ANSI/NFPA 70-latest edition.

(In Canada, the current CSA C22-1

Canadian Electrical Code).

CAUTION: Label all wires prior to disconnec-

tion when servicing controls. Wiring errors can

cause improper and dangerous operation.

ATTENTION: Au moment de l'entretien des

commandes, étiquetez tous les fils avant de

les débrancher. Des erreurs de cáblage peu-

vent entraîner un fonctionnement inadéquat

et dangereux.

Verify proper operation after servicing.

S'assurer que l'appareil fonctionne adé-

quatement une fois l'entretien terminé.

See Figure 38 for detailed drawing of junction box / receptacle wiring