• A hard wired carbon monoxide detector

with an alarm and battery back-up must be

installed on the floor level where the gas

fireplace is installed. The carbon monoxide

detector must comply with NFPA 720, be

ANSI/UL 2034 listed and be ISA certified.

• A metal or plastic identification plate must

be permanently mounted to the exterior of

the building at a minimum height of eight (8)

feet above grade and be directly in line with

the horizontal termination. The sign must

read, in print size no less than one-half (1/2)

inch in size, GAS VENT DIRECTLY BELOW.

KEEP CLEAR OF ALL OBSTRUCTIONS.

NEW YORK CITY, NEW YORK (MEA)

Installation of these fireplaces are approved

for installation in New York City in the US state

of New York.

COLD CLIMATE INSULATION

For cold climate installations, seal all cracks

around your appliance with noncombustible

material and wherever cold air could enter

the room. It is especially important to insulate

outside chase cavity between studs and under

floor on which appliance rests, if floor is above

ground level. Gas line holes and other open-

ings should be caulked or stuffed with unfaced

fiberglass insulation.

If the fireplace is being installed on a cement

slab in cold climates, a sheet of plywood or

other raised platform can be placed underneath

to prevent conduction of cold transferring to

the fireplace and into the room. It also helps to

sheetrock inside surfaces and tape for maximum

air tightness and caulk firestops.

MANUFACTURED HOME

REQUIREMENTS

This appliance may be installed in an aftermarket

permanently located, manufactured home and

must be installed in accordance with the manu-

facturer's instructions and the Manufactured

Home Construction and Safety Standard, Title

24 CFR, Part 3280, in the United States, or the

Standard for Installation in Mobile Homes, CAN/

CSA Z240 MH Series, in Canada.

Cet appareil peut être installé cómme du matéri-

el d'origine dans une maison préfabriquée (É.U.

seulement) ou mobile et doit être installé selon

les instructions du fabricant et conformément

à la norme Manufactured Home Constructions

and Safety, Title 24 CFR, Part 3200 aux Unis ou

à la norme Can/CSA-Z240 Série MM, Maisons

mobiles au Canada.

Figure 3

-

Typical Locations

N

O

IT

A

CI

L

P

P

A

T

N

E

V

P

O

T

APPLICATION

TOP VENT

TN

EV

PO

T

NOI

TA

CI

LP

PA

RECESSED

INSTALLATION

TOP VENT

APPLICATION

NOI

TA

CI

LP

PA

TN

EV

PO

T

NOI

TA

CI

LP

PA

TN

EV

PO

T

HORIZONTAL VENT

(Top Vent Application)

VERTICAL VENT

(Top Vent Application)

Note: When the unit is installed with one

side flush with a wall, the wall on the other

side of the unit must not extend beyond the

front edge of the unit.

LOCATION

In selecting the location, the aesthetic and

functional use of the appliance are primary

concerns. However, vent system routing to

the exterior and access to the fuel supply are

also important.

Due to high temperatures, the appliance

should be located out of traffic and away from

furniture and draperies (Figure 3).

En raison des températures élevées, l’appareil

devrait être installé dans un endroit où il y a

peu de circulation et loin du mobilier et des

tentures (Figure 3).

The location should also be free of electrical,

plumbing or other heating/air conditioning

ducting.

These direct-vent appliances are uniquely

suited for installations requiring a utility shelf

positioned directly above the fireplace. Utility

shelves like these are commonly used for locat-

ing television sets and decorative plants.

This appliance is only for use with the type of gas

indicated on the rating plate. This appliance is

not convertible for use with other gases, unless

a certified kit is used.

Cet appareil doit être utilisé uniquement avec le

type de gaz indiqué sur la plaque signalétique.

Cet appareil ne peut être converti à d'autres gaz,

sauf si une trousse de conversion est utilisée.

CAUTION: Ensure that the cross mem-
bers are not cut or weakened during
installation. The structural integrity of
the manufactured home floor, wall, and
ceiling / roof must be maintained.

CAUTION: This appliance must be ground-
ed to the chassis of the manufactured
home in accordance with local codes or
in the absence of local codes, with the
National Electrical Code ANSI / NFPA 70
- latest edition or the Canadian Electrical
Code CSA C22.1 - latest edition.