Lennox Hearth ELITE ELDV-40NM User Manual

Page 26

Advertising
background image

26

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Figure 40

Step 6. CONNECTING GAS LINE

All codes require a shut-off valve mounted

in the supply line. The orientation of the

shut-off valve should face the front. Figure

39 illustrates two methods for connecting the

gas supply. A sediment trap is recommended

in the gas piping within the home to prevent

moisture and debris in the line from damaging

the valve.

The flex-line method is acceptable in the U.S.A.

where local codes permit, however, Canadian

requirements vary depending on locality. Instal-

lation must be in compliance with local codes.

These appliances are equipped with a gas flex

line for use in connecting the unit to the gas line.

See Figure 39 for flex line description. The

flex line is rated for both natural and propane

gas. A manual shut off valve is also provided

with the flex line.

The gas control valve is located in the lower

control compartment.

Access the valve compartment by removing the

lower control compartment panel (see Figure

40) by lifting and pulling the panel forward.

The panel is mounted on supporting tabs at

the extreme right and left hand sides. Engage

the tabs into the reliefs in the panel.

The millivolt and electronic control valve has a

3/8" (10 mm) NPT thread inlet port.

Secure all joints tightly using appropriate

tools and sealing compounds (ensure propane

resistant compounds are used in propane ap-

plications). It is recommended to seal around

the gas line to prevent cold air leakage.

These appliances come from the factory with

the gas line access plate removed to provide full

access to the end of the gas flex line.

As designed, the glass door needs to be opened

to access the open gas access area.

Acquire the shut-off valve and gas flex line and

pull the assembly forward, out of the compart-

ment. Separate the shut-off valve from the gas

flex line. Determine the length of pipe needed to

route the gas line form the last fitting to a point

directly below the access plate opening.

Using pipe-dressing materials appropriate for

the gas type, securely affix the shut-off valve

to this determined pipe length at a convenient

location outside of the appliance lower control

compartment.

Refer to Figure 41 and insert the last length

of gas pipe with its attached shut-off valve

into the lower control compartment, and pass

it through the gas line access hole on the left

side of the appliance outer wrapper.

Using appropriate materials for the gas type,

thread the last length of pipe into the end of the

gas vent run and tighten in place using a pipe

wrench external to the appliance between the

appliance outer wrapper and the framing.

GAS CONNECTION

Note: The gas supply line must be installed in accordance with building codes by a quali-

fied installer approved and/or licensed as required by the locality. In the Commonwealth

of Massachusetts, installation must be performed by a licensed plumber or gas fitter.

Figure 39

Important: Turn the last piece of gas pipe in

the last fitting until the shut-off valve is posi-

tioned in a way that allows the shut-off valve

handle to be accessed in the lower control

compartment, easily operated throughout its

full range of motion.

Bring the flex line to the shutoff valve by hand

and align the flare fittings. Tighten the fittings

by hand, and then use wrench to tighten com-

pletely, 1/4 turn at a time.

Gas

Stub

1/2" x 3/8" Flare

Shut-Off Valve

3/8" Flex Tubing

3/8" NPT x 3/8"

Flare Fitting

Gas

Valve

Flex Line Connector

Piezo Ignitor

Gas

Supply

Line

ON/OFF

Switch

ON

OFF

Shut-Off Valve

(Orientation

As Shown)

Gas Valve

Air Shutter

Adjustment Arm

Gas Line Access Plate Not Installed

At The Factory. It Is Included In

The Installation Instruction Bag.

Right Corner Post

Advertising