Warnings, Cautions – Lennox Hearth ELITE ELDV-40NM User Manual

Page 33

Advertising
background image

33

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

WARNINGS

Air shutter adjustment should

only be performed by a quali-

fied professional service tech-

nician.

Ensure front glass panel are

in place and sealed during

adjustment.

CAUTIONS

Soot will be produced if the

air shutter is closed too much.

Any damage due to sooting

resulting from improperly

setting the air shutter is not

covered under the warranty.

The air shutter door and nearby

appliance surfaces are hot.

Exercise caution to avoid

injury while adjusting flame

appearance.

Figure 50 (Burner & Flame Appearance Model) ELDV35 (With Optional Brick Liner Kit)

Figure 51 (Burner & Flame Appearance Model) ELDV40 (With Optional Brick Liner Kit)

Figure 52

(Burner & Flame Appearance Model) ELDV45

1. Locate adjustment rod and adjust air

shutter to the standard setting as shown

in Figure 53 (adjustment rod is located in

the lower control compartment).

Note: Move the adjustment rod down to

decrease air and up to increase.

2. Light appliance (follow lighting procedure

on lighting label in control compartment

or see the Care and Operation Manual).

3. Allow the burner to operate for at least

15 minutes while observing the flame

continuously to ensure that the proper

flame appearance has been achieved (see

Figures 50 through 52). If the following

conditions are present, adjust accordingly.

• If flame appears weak or sooty, adjust

the air shutter, incrementally, to a

more open position until the proper

flame appearance is achieved.

• If flame remains blue, adjust the air

shutter, incrementally, to a more

closed position until the proper flame

appearance is achieved.

4. Leave the control knob (off/pilot/on)

in the ON position and the burner OFF/

ON switch OFF (and remote switches, if

applicable).

5. When satisfied that the burner flame ap-

pearance is normal, re-install the lower

control compartment door then proceed

to finish the installation.