Lennox Hearth ELITE ELDV-40NM User Manual

Page 8

Advertising
background image

8

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

5 (127)

8-1/4

(209)

14

(356)

12 (305)

17 (431)

*Shelf Height

(

see table)

Do not insulate the

space between the

appliance and the

area above it.

Shelf Above Fireplace With Top Venting

6 (152)

2

(51)

4

(102)

6

(152)

8

(203)

10

(254)

12

(305)

8 (203)

12 (305)

16 (457)

14 (356)

10 (254)

Top of

Appliance

inches (millimeters)

Mantel Depth

Figure 9 -

Minimum Mantel Clearances

Header

Model No.

Combustible Shelf Height - Inches (millimeters)

Top Vent - with One 90 Degree Elbow

Secure Vent

Secure Flex (flex elbow)

ELDV35

ELDV40

ELDV45

*63-1/8 (1603)

*64-7/8 (1648)

Figure 10 -

Minimum Distance to Unprotected Side Wall

Top View of

Fireplace

45

o

Protected wall shown in white

Inches (millimeters)

MINIMUM CLEARANCES TO COMBUSTIBLES

Appliance And Vent Clearances

The appliance is approved with zero clearance to combustible materials on

all sides (as detailed in Table 6 ), with the following exception: When the

unit is installed with one side flush with a wall, the wall on the other

side of the unit must not extend beyond the front edge of the unit. In

addition, when the unit is recessed, the side walls surrounding the unit

must not extend beyond the front edge of the unit (see Figure 3).

*Note: 3 in. (76 mm) above any horizontal/inclined vent component.

**Note: See Page 9, Step 1 for clearance requirements to the nailing

flange located at each side of the unit and any screw heads adjacent

to it.

Hearth Extension

- A hearth extension is not required with this appliance.

If a hearth extension is used, do not block the lower control compartment

door. Any hearth extension used is for appearance only and does not have

to conform to standard hearth extension installation requirements.

Shelf Height -

To provide for the lowest possible shelf surface, the venting

attached to the top vent should be routed in a way to minimize obstructions

to the space above the appliance. Do not insulate the space between the

appliance and the area above it (see Figure 8). The minimum height from

the base of the appliance to the underside of combustible materials used

to construct a utility shelf in this fashion is shown in Figure 8.

Wall Finishes / Surrounds / Mantels

Note: Combustible wall finish materials and/or surround materials

must not be allowed to en-croach the area defined by the appliance

front face (black sheet metal). Never allow combustible materials

to be positioned in front of or overlapping the appliance face (see

Figure 10 and Figure 54 on Page 34).

Non-combustible materials, such as surrounds and other appliance trim,

may be installed on the appliance face with these exceptions: they must

not cover any portion of the removable glass panel.

Vertical installation clearances to combustible mantels vary accord-

ing to the depth of the mantel. See Figure 9. Mantels constructed of

non-combustible materials may be installed at any height above the

appliance opening; however, do not allow anything to hang below the

fireplace hood.

* Includes 3” clearance to

combustibles (required above

vent components)

Combustible materials may

project beyond one side

of the fireplace opening

as long as they are kept

within the shaded areas

illustrated here.

Combustible Materials

Allowed In Shaded Area

“Safe Zone”
Combustible Walls

shown in dark gray

At 14" minimum

side wall clearance,

a combustible wall

can project to any

length.

At 8-1/4" side

wall clearance, a

combustible wall

can project 12"

Figure 8 -

Shelf Height Minimum Clearances With Top Venting

MINIMUM CLEARANCES

*

Inches (millimeters)

Back

1 in. (25.4) to wrapper

0 (0) to Spacers

Sides

1 in. (25.4) to wrapper

0 (0) to Spacers **

Top Spacers

0 (0)

Floor

0 (0)

From Bottom of Unit To Ceiling

64 (1626)

Vent

3 (76)

Top

* / 1 (25.4)

Sides & Bottom

SERVICE CLEARANCES

Feet (meters)

Front

3 feet (0.9 meters)

Table 6

Advertising