Lennox Hearth ELITE ELDV-40NM User Manual

Page 25

Advertising
background image

25

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Note: Remote receiver should be located in the

wall, or if installed in the control compartment,

pulled all the way forward and completely to the

left or right against the corner posts. The door

must be removed first to place the receiver in

the lower control compartment.

7. If wall-mounted ON/OFF control or thermo-

stat is to be used, mount it in a convenient

location on a wall near the fireplace.

8. If an optional control is to be used, wire it in

the low voltage circuit as shown in Figure

37.

Note: The supplied 15 feet of 2 conductor wire

has one end of each conductor connected

to the gas valve circuit and the other end

of each conductor placed loose inside the

bottom compartment.

9. If the optional unit mounted (FRS) control

switch is installed, turn the appliance-

mounted ON/OFF burner control switch to

the OFF position.

10. After the wiring is complete, replace the

cover plate.

Note: No batteries to be installed in the battery

holder until a power outage, or if the appli-

ance is to be operated solely with two (2) "D"

batteries.

BLOWER CONTROL CIRCUIT WIRING

120V, 60HZ, 1PH

Factory Wired

Ground

Field Wired

Junction Box

Tab Intact

Tab

Broken

Plug blower

into this

receptacle

ne

er

G -

dn

uor

G

* Wall-mounted

ON/ OFF Blower

Switch or Variable

Speed Control Switch.

Blower

eti

h

W -

lar

tu

eN 12

0

VA

C

- B

la

ck

Green

Ground

Screw

W

hi

te

Gr

ee

n

Neutral

Side of

Receptacle

Hot

Side of

Receptacle

Red

Black

Figure 38 -

J-BOX WIRING

Step 5.

WIRING - OPTIONAL FORCED AIR

BLOWER KIT

Blower Access

Blower access is through the firebox bottom.

Remove the sub-floor, remove the burner and

remove ten screws securing the GTA assembly

to the firebox.

An electrical outlet box is provided for the

installation of the LBLK-100 forced air blower

kit. Electrical power must be provided to this

box to operate these blowers.

Install the blower kit according to the installation

instructions provided with the kit. Reposition

and reinstall the GTA assembly, burner and

sub-floor.

Advertising