Lennox Hearth ELITE ELDV-40NM User Manual

Page 4

Advertising
background image

4

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Figure 2 -

Dexen Electronic Gas Valve

Pilot Stage

Terminal

Pressure-Tap

(Inlet)

Pilot Gas

Outlet

Supply

Gas

Inlet

Pressure-Tap

(Manifold)

Burner Stage

Terminal

Ground

(TP)

PILOT

OUT

VENT

LO

TH TP

TH

TP

HI

IN

IN

Regulator

Mounting Screw

Test gauge connections are provided on the

front of the millivolt and electronic gas control

valve (identified IN for the inlet and OUT for the

manifold side). The control valves have a 3/8"

(10mm) NPT thread inlet and outlet side of the

valve (refer to Figures 1 and 2).

Propane tanks are at pressures that will cause

damage to valve components. Verify that the

tanks have step down regulators to reduce the

pressure to safe levels.

Gas Valve Diagrams

See Figure 1 for Millivolt models and Figure 2

For Electronic Models.

Manifold Gas Supply Pressure

(all models)

Fuel #

Low

High

Natural

Gas

(Lo) 2.2" WC

(0.55 kPa)

(Hi) 3.5" WC

(0.87 kPa)

Propane (Lo) 6.3" WC

(1.57 kPa)

(Hi) 10.0" WC

(2.49 kPa)

Table 4

Burner Orifice Sizes

Elevation 0-4500 feet ( 0-1372 meters)

Model

Series

Nat.Gas

drill size (inches)

Propane

drill size (inches)

ELDV35

#38 (0.1015")*

99K76•

#53 (0.0595")*

39L10•

ELDV40

#37 (0.1040")*

24M10•

(0.062")*

21L01•

ELDV45

#36 (0.1065")*

74L88•

#52 (0.0635")*

80L41•

Table 5

REQUIREMENTS FOR THE COMMON-

WEALTH OF MASSACHUSETTS

These fireplaces are approved for installation in

the US state of Massachusetts if the following

additional requirements are met:

• Install this appliance in accordance with

Massachusetts Rules and Regulations 248

C.M.R.

• Installation and repair must be done by a

plumber or gas fitter licensed in the Com-

monwealth of Massachusetts.

• The flexible gas line connector used shall

not exceed 36 inches (92 centimeters) in

length.

• The individual manual shut-off must be a

T-handle type valve.

Massachusetts Horizontal Vent Requirements

In the Commonwealth of Massachusetts, hori-

zontal terminations installed less than seven

(7) feet above the finished grade must comply

with the following additional requirements:

Inlet Gas Supply Pressure

(all models)

Fuel #

Minimum

Maximum

Natural Gas

4.5" WC

(1.12 kPa)

10.5" WC

(2.61 kPa)

Propane

11.0" WC

(2.74 kPa)

13.0" WC

(3.23 kPa)

Table 3

Gas Pressure - All Models
Tables 3 and 4
show the appliances' inlet and

manifold gas pressure requirements:

These appliances must not be connected to a

chimney or flue serving a separate solid fuel

burning appliance.

Orifice Sizes - Sea Level to High Altitude

(All Models)

These appliances are tested and approved for

installation at elevations of 0-4500 feet (0-1372

meters) above sea level using the standard burner

orifice sizes (marked with an "*" in Table 5).

For elevations above 4500 feet, contact your gas

supplier or qualified service technician .

Deration - At higher elevations, the amount

of BTU fuel value delivered must be reduced

by either:

• Using gas that has been derated by the gas

company.

• By changing the burner orifice to a smaller

size as regulated by the local authorities having

jurisdiction and by the (USA) National Fuel Gas

Code NFPA 54/ANSI Z223.1 - latest edition or,

in Canada, the CAN/CSA-B149.1 codes - latest

edition.

Install the appliance according to the regulations

of the local authorities having jurisdiction and,

in the USA, the National Fuel Gas Code NFPA

54 / ANSI Z223.1 - latest edition or, in Canada,

the CAN/CSA-B149.1 - latest edition.

Flame breadth, height and width will diminish

4% for every 1,000 feet of altitude.

These appliances must be isolated from the

gas supply piping system (by closing their

individual manual shut-off valve) during any

pressure testing of the gas supply piping

system at test pressures equal to or less

than 1/2 psig (3.5 kPa).

These appliances and their individual shut-off

valves must be disconnected from the gas

supply piping system during any pressure

testing of that system at pressures greater

than 1/2 psig (3.5 kPa).

H I

LO

W

HT

PT

HT

PT

PILO

T

PI

LO

T

ON

it

OFF

IN

OUT

HI/LO Variable

Flame Height

Adjustment

* Standard size installed at factory

• Part /Cat. Number

Figure 1 -

SIT Millivolt Gas Valve

Manifold Pressure Tap

Inlet Pressure Tap

Pilot Adjustment

Screw

Main Gas Control Knob

OFF/PILOT/ON

Input (BTU/HR) (all models)

Models

Input Rate (BTU / HR)

Natural Gas

Propane Gas*

ELDV35

27,000 high

21,000 low

26,000 high

20,000 low

ELDV40

29,000 high

23,000 low

27,000 high

22,000 low

ELDV45

30,000 high

23,000 low

28,000 high

21,000 low

Table 2

These electronic models come standard with a

manually-modulated gas valve; flame appear-

ance and heat output can be controlled at the

gas valve. The BTU Input for these appliances

is shown in Table 2.

*Electronic valves may be

converted to propane.