Table 9-8.

REPT-OPSTAT-VCL Response Parameters

Parameter Explanation

tid Target

NE

identification

yy-mm-dd

Year, month, and day

hh:mm:ss

Hour, minute, and second

M

Message generated in response to an input command

c

If provided, ctag; otherwise 0

COMPLD Completed

DENY

Input command is denied

/* */

Enclosed are human readable comments – unspecified format

errcde Error

code

(see

Appendix A,

Error Codes

)

aid_vcl

As described for command parameters (see

Table 9-7,

REPT-OPSTAT-VCL Command Parameters

).

[op_vcl]

VCL operational parameters. Values are:

INCELLS: Rolling count of cells received on this VCL

OUTCELLS: Rolling count of cells transmitted on this VCL

LPBKINCELLS: A count of test cells received since the test started (up
to 2

32

-1)

LPBKOUTCELLS: A count of test cells received since the test started
(up to 2

32

-1)

LPBKRTDELAY: Average round trip delay in milliseconds since the test
has started. Only calculated on cells received; dropped cells are not
counted.

LPBKMNRTDELAY: Shortest round trip delay in milliseconds since the
test has started. Only calculated on cells received; dropped cells are not
counted.

LPBKMXRTDELAY: Longest round trip delay in milliseconds since the
test has started. Only calculated on cells received; dropped cells are not
counted.

LPBKTYPE: The type of OAM loopback test, if any, most recently
performed on the VCL:

– E2E: End-to-End OAM cell

– SEG: Segment OAM cell

– NOTST: No test has been performed on the VCL

LPBKSEGID: The ATM segment location identifier for the segment
loopback or blank.

value

Value of parameter specified by op_vcl