15. Test Commands

4200-A2-GB20-00

August 2002

15-7

RLS-LPBK-T1

The RLS-LPBK-T1 command releases any loopback currently active at the near
end of a specific T1 facility, including configured loopbacks (set with the command

OPR-LPBK-T1

on page 15-2) and inband loopbacks (set with DS1 inband

loopback codes).

Response Format

If, in less than 2 seconds, a normal or error response cannot be sent, the following
acknowledgment response is sent:

IP c

After the above response, a new command input may be generated.

Normal Response:

sid yy-mm-dd hh:mm:ss
M c COMPLD
/* RLS-LPBK-T1:[tid]:aid_ds1:[ctag][:] */
;

Error Response:

sid yy-mm-dd hh:mm:ss
M c DENY
/* RLS-LPBK-T1:[tid]:aid_ds1:[ctag][:] */
aid:ERRCDE=errcde
/* error description */
;

Table 15-5.

RLS-LPBK-T1 Command Parameters

RLS-LPBK-T1:[tid]:aid_ds1:[ctag][:];

RESTRICTIONS:

T

All parameters in this command are position-defined.

T

Port loopbacks are supported only on LT ports.

[tid]

Identification of the target NE. The default value is null. The NE SID
code is the only other valid value.

aid_ds1

Access Identifier for the T1 facility. The value can be preceded with
AID=, but this is not required. Enter in the following format, replacing
lower-case parameters with the values given:

NTT1-circuit

– circuit: DS1 circuit on the NT (1)

[ctag]

Correlation tag (6 characters maximum) that links an input command
with associated output responses. The default is 0.