15. Test Commands
4200-A2-GB20-00
August 2002
15-3
Error Response:
sid yy-mm-dd hh:mm:ss
M c DENY
/* OPR-LPBK-T1:[tid]:aid_ds1:[ctag]::,,,[lpbktype] */
aid:ERRCDE=errcde
/* error description */
;
Example
Place NTT1 circuit 1 in payload loopback mode.
OPR-LPBK-T1:TAMPA:NTT1-1:40::,,,PAYLOAD;
TAMPA 01-11-24 12:30:43
M 40 COMPLD
/* OPR-LPBK-T1:TAMPA:NTT1-1:40::,,,PAYLOAD */
;
Related Command
Table 15-2.
OPR-LPBK-T1 Response Parameters
Parameter Explanation
sid Source
NE
identification
yy-mm-dd
Year, month, and day
hh:mm:ss
Hour, minute, and second
M
Message generated in response to an input command
c
If provided, ctag; otherwise 0
COMPLD Completed
DENY
Input command is denied
/* */
Enclosed are human readable comments – unspecified format
errcde Error
code