4. DS1 Facility Commands

4-6

August 2002

4200-A2-GB20-00

Response Format

If, in less than 2 seconds, a normal or error response cannot be sent, the following
acknowledgment response is sent:

IP c

After the above response, a new command input may be generated.

Normal Response

sid yy-mm-dd hh:mm:ss
M c COMPLD
/* ENT-T1:[tid]:aid_ds1:[ctag]:::ds1_nblk:[pst] */
;

ds1_nblk

(continued)

For the following parameters if no value is specified, null is assumed.

ATMACCPROF: ATM Access Profile index (1). This value determines
the range of values for vpi and vci in several other commands. The
value cannot be changed while any VPLs or VCLs exist.

ATMACCPROFNM: ATM Access Profile name. The default is NT
DEFVAL.

QOSCLASS: Quality of service of connections on this port. The valid

[pst]

Desired state. Valid values are:

IS: In service (default)

OOS: Out of service. OOS-MA (out of service, management) is implied.

If no value is specified, this parameter is set to IS.

Table 4-4.

T1 Line Equalization Values

EQLZ value

Cable length (feet)

Equalization (dB)

0 (default)

0

−

133

0.6

200

134

−

266

1.2

300

267

−

399

1.8

500

400

−

533

2.4

600

534

−

655

3.0

Table 4-3.

ENT-T1 Command Parameters (2 of 2)

ENT-T1:[tid]:aid_ds1:[ctag]:::ds1_nblk:[pst];