Set line interface – Perle Systems IOLAN SDS User Manual

Page 72

Advertising
background image

Line Commands

72

IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7

Set Line Interface

The SCS, STS, and MDC IOLAN models support the EIA-232 interface only. Therefore, you do not
need to specify

interface eia-232

in the command syntax; you only need to specify the

command options (e.g.,

monitor-dcd

).

Description Configures line interface (hardware) parameters.
User Level Admin
Syntax

set line .|<number>|* interface eia-232 [monitor-dcd on|off]

[monitor-dsr on|off] [flow none|soft|hard|both]
[speed 50|75|110|134|150|200|300|600|1200|1800|2400|4800|9600|
19200|38400|57600|115200|230400|28800|custom <baud_rate>]

set line .|<number>|* interface eia-422

[flow none|soft|hard|both]
[speed 50|75|110|134|150|200|300|600|1200|1800|2400|4800|
9600|19200|38400|57600|115200|230400|28800|
custom <baud_rate>]]

set line .|<number>|* interface eia-485-half-duplex

[tx-driver-control auto|rts] [flow none|soft]
[echo-suppression on|off]]
[speed 50|75|110|134|150|200|300|600|1200|1800|2400|4800|
9600|19200|38400|57600|115200|230400|28800|custom <baud_rate>]

set line .|<number>|* interface eia-485-full-duplex

[tx-driver-control auto|rts] [flow none|soft]
[speed 50|75|110|134|150|200|300|600|1200|1800|2400|4800|
9600|19200|38400|57600|115200|230400|28800|custom <baud_rate>]

Options

eia-232 | eia-422 | eia-485-half-duplex|eia-485-full-duplex

Specifies the type of serial line that is being used with the IOLAN. Specify either

EIA-232, EIA-422, EIA-485-half-duplex, or EIA-485-full-duplex. The STS, SCS, and
MDC models support only EIA-232.

monitor-dcd

Specifies whether the RS-232 signal DCD (Data Carrier Detect) should be monitored.

This is used with modems or any other device that sends a DCD signal. When it is
monitored and the IOLAN detects a DCD signal, the line service is started. Default is

Off

. If both

Monitor DCD

and

Monitor DSR

are enabled, both signals must be detected

before the line service is started.

monitor-dsr

Specifies whether the RS-232 signal DSR (data set ready) should be monitored. This is
used with modems or any device that sends a DSR signal. When it is monitored and the

IOLAN detects a DSR signal, the line service is started. Default is

Off

. The

Monitor

DSR

parameter is not available for medical unit models. If both

Monitor DCD

and

Monitor DSR

are enabled, both signals must be detected before the line service is

started.

flow

Defines whether the data flow is handled by the software (

Soft

), hardware (

Hard

),

Both

, or

None

. If you are using

SLIP

, set to

Hard

only. If you are using

PPP

, set to

either

Soft

or

Hard

(

Hard

is recommended). If you select

Soft

with

PPP

, you must set

the

ACCM

parameter when you configure

PPP

for the

Line

.

Advertising