Chapter 3 Using the console interface

125

Using the BayStack 420 10/100/1000 Switch

VLAN Port Configuration screen

The VLAN Port Configuration screen (

Figure 56

) allows you to configure

specified switch ports with the appropriate PVID/VLAN association that enables
the creation of VLAN broadcast domains (see

“Shared servers” on page 63

for

more information about setting up VLAN broadcast domains).

You can configure specified switch ports to filter (discard) all received untagged
frames (see

“IEEE 802.1Q VLAN workgroups” on page 54

).

To open the VLAN Port Configuration screen.

When the Tagging field is set to Tagged Trunk, you can set the Port Membership
field as a tagged port member (T) or as a non-VLAN port
member (-).

The Port Membership fields are displayed in six-port groups (for example, 1-6, 7-12,
13-18). The number of ports displayed depends on the switch model or type of
optional GBIC installed in the Uplink Module slot.

Default

U (All ports are assigned as untagged members of VLAN 1.)

Range

U, T, and -

Choose VLAN Port Configuration (or press c) from the VLAN
Configuration Menu screen.

Table 21 VLAN Configuration screen fields (continued)

Field

Description