Table 38, Telnet configuration screen fields – Nortel Networks 1000ASE-XD User Manual

Page 165

Advertising
background image

Chapter 3 Using the console interface

165

Using the BayStack 420 10/100/1000 Switch

Table 38

describes the TELNET Configuration screen fields.

Table 38 TELNET Configuration screen fields

Field

Description

TELNET Access Allows a user remote access to the CI through a Telnet session.

Default Value:

Enabled

Range:

Enabled, Disabled

Login Timeout

Specifies the amount of time a user has to enter the correct password at the
console-terminal prompt.

Default Value:

1 minute

Range:

0 to 10 minutes (0 indicates “no timeout”)

Login Retries

Specifies the number of times a user can enter an incorrect password at the
console-terminal prompt before terminating the session.

Default Value:

3

Range:

1 to 100

Inactivity
Timeout

Specifies the amount of time the session can be inactive before it is terminated.

Default Value:

15 minutes

Range:

0 to 60 minutes (0 indicates “no timeout”)

Event Logging

Specifies the types of events that will be displayed in the Event Log screen (see

“System

Log screen” on page 145

.

Default Value:

All

Range:

All, None, Accesses, Failures

Description:

All: Logs the following Telnet events to the Event Log screen:

TELNET connect: Indicates the IP address and access mode of a
Telnet session.

TELNET disconnect: Indicates the IP address of the remote host
and the access mode, due to either a logout or inactivity.

Failed TELNET connection attempts: Indicates the IP address of
the remote host whose IP address is not on the list of allowed
addresses, or indicates the IP address of the remote host that did
not supply the correct password.

None: Indicates that no Telnet events will be logged in the Event Log
screen.

Accesses: Logs only Telnet connect and disconnect events in the
Event Log screen.

Failures: Logs only failed Telnet connection attempts in the Event Log
screen.