Figure 22, Default vlan configuration screen example – Nortel Networks 1000ASE-XD User Manual

Page 65

Advertising
background image

Chapter 2 Network configuration

65

Using the BayStack 420 10/100/1000 Switch

To configure the VLAN port membership for VLAN 1:

1

Select Switch Configuration from the BayStack 420 Switch Main Menu
(or press w).

2

From the Switch Configuration Menu, select VLAN Configuration
(or press v).

3

From the VLAN Configuration Menu select VLAN Configuration
(or press v).

The default VLAN Configuration screen opens (

Figure 22

).

Figure 22 Default VLAN Configuration screen example

The VLAN Configuration screen settings shown in

Figure 22

are default settings

with all switch ports classified as untagged members of VLAN 1.

Figure 23

shows the VLAN Configuration screen after it is configured to support

the VLAN 3 broadcast domain shown in

Figure 21 on page 64

(VLAN Name is

optional).