Nortel Networks Mediant TP-1610 SIP User Manual

Page 104

Advertising
background image

Mediant 2000 SIP

Mediant 2000 SIP User’s Manual

104

Document #: LTRT-72504

Table

6-3: SIP Configuration Parameters (continues on pages 100 to 110)

ini File Field Name

Web Parameter Name

*

Valid Range and Description

CoderName
[Coders]

CoderName = Coder,ptime (can appear up to 5 times)
The following coder names can be selected:
g711Alaw64k

– G.711 A-law.

g711Ulaw64k –

G.711

µ-law.

g7231

– G.723.1 6.3 kbps (default).

g7231r53

– G.723 5.3 kbps.

g726

– G.726 ADPCM 32 kbps (Payload Type = 2).

g729 –

G.729A.

NetCoder6_4

– NetCoder 6.4 kbps.

NetCoder7_2

– NetCoder 7.2 kbps.

NetCoder8

– NetCoder 8.0 kbps.

NetCoder8_8

– NetCoder 8.8 kbps.

Transparent

– Transparent coder.

Evrc

– EVRC coder.

Amr

– AMR coder.

Note:

The coder name is case-sensitive.


The RTP packetization period (ptime, in msec) depends on the selected Coder name,
and can have the following values:

g711 family

– 10,20,30,40,50,60,80,100,120 (default=20).

g729 –

10,20,30,40,50,60,80,100 (default=20).

g723 family

– 30,60,90,120 (default = 30).

G.726

– 10, 20, 40, 60, 80, 100, 120 (default=20).

NetCoder family

– 20, 40, 60, 80, 100, 120 (default=20).

EVRC

– 20, 40, 60, 80, 100 (default=20).

AMR

– 20 only.

Transparent

- 20, 40, 60, 80, 100, 120 (default=20)


Note 1:

If not specified, the ptime gets a default value.

Note 2:

Each coder should appear only once.

Note 3:

The ptime specifies the maximum packetization time the gateway can receive.

Note 4:

G.729B is supported if the coder G.729 is selected and

‘EnableSilenceCompression’ equals 1 or 2.
Note 5:

The selected rate of the AMR coder is set according to the parameter

‘AMRSendRate’. The selected rate of the EVRC coder is set according to the
parameter ‘EVRCRate’.
Note 6:

The AMR coder is enabled only if ‘DSPVersionTemplateNumber = 1’. When

this DSP template is selected, the maximum number of channels is 160 instead of 240
(rounded to full E1/T1 trunk capacity 30/24 channels per trunk).
Note 7:

The EVRC coder is enabled only if ‘DSPVersionTemplateNumber = 2’. When

this DSP template is selected, the maximum number of channels is 120 instead of 240
(rounded to full E1/T1 trunk capacity 30/24 channels per trunk). Note that the value of
the parameter ‘EnableRFC2658Interleaving’ must be identical on both sides of the call.

For example:
CoderName = g711Alaw64k,20
CoderName = g711Ulaw64k,40
CoderName = g7231,90

AMRPayloadType

Determines the payload type that is used when the selected coder is set to one of the
AMR coder variants.
The valid range is 0 to 120. The default value is 64.