Default counter terminals, Default counter terminals -30, Default – National Instruments DAQ M Series User Manual

Page 92: Counter terminals, Section

Advertising
background image

Chapter 7

Counters

NI 6236 User Manual

7-30

ni.com

Default Counter Terminals

By default, NI-DAQmx routes the counter/timer inputs and outputs to the
PFI pins, shown in Table 7-4.

You can use these defaults or select other sources and destinations for the
counter/timer signals in NI-DAQmx. Refer to Connecting Counter Signals
in the NI-DAQmx Help or the LabVIEW 8.x Help for more information
about how to connect your signals for common counter measurements and
generations. M Series default PFI lines for counter functions are listed in
Physical Channels in the NI-DAQmx Help or the LabVIEW 8.x Help.

Table 7-4. NI 6236 Device Default NI-DAQmx Counter/Timer Pins

Counter/Timer Signal

Default Pin Number (Name)

Port

CTR 0 SRC

13 (PFI 0)

P0.0

CTR 0 GATE

32 (PFI 1)

P0.1

CTR 0 AUX

33 (PFI 2)

P0.2

CTR 0 OUT

17 (PFI 6)

P1.0

CTR 0 A

13 (PFI 0)

P0.0

CTR 0 Z

32 (PFI 1)

P0.1

CTR 0 B

33 (PFI 2)

P0.2

CTR 1 SRC

15 (PFI 3)

P0.3

CTR 1 GATE

34 (PFI 4)

P0.4

CTR 1 AUX

35 (PFI 5)

P0.5

CTR 1 OUT

36 (PFI 7)

P1.1

CTR 1 A

15 (PFI 3)

P0.3

CTR 1 Z

34 (PFI 4)

P0.4

CTR 1 B

35 (PFI 5)

P0.5

FREQ OUT

37 (PFI 8)

P1.2

Advertising