Digital trigger, Vxibus trigger, Power requirement – National Instruments VXI-MIO Series User Manual
Page 110: Physical, Environment

Appendix A Specifications for VXI-MIO-64XE-10
VXI-MIO Series User Manual
A-16
National Instruments Corporation
External input (PFI0/TRIG1)
Impedance .................................. 10 k
Ω
Coupling ..................................... DC
Protection ................................... -0.5 to 5.5 V when configured as
a digital signal;
±
35 V when configured as an
analog trigger signal or disabled;
±
35 V powered off
Accuracy............................................
±
1% of fullscale range
Digital Trigger
Compatibility .....................................TTL
Response............................................Rising or falling edge
Pulse width ........................................10 ns min
VXIbus Trigger
Trigger lines.......................................Supports 5 TTL and 2 ECL
trigger lines
Power Requirement
+5 VDC .............................................2.82 A typ; 3.38 A max*
(*Not including current used by
accessories.)
-5.2 VDC ...........................................0.15 A typ; 0.18 A max
-2 VDC ..............................................0.04 A typ; 0.06 A max
Power available at I/O connector .......+4.65 VDC to +5.25 VDC
at 1 A
Physical
Dimensions .......................................VXI C-size single slot
I/O connector .....................................96-pin DIN
Environment
Operating temperature........................0 to 55
°
C
Storage temperature ...........................-20 to 70
°
C
Relative humidity...............................5% to 90% noncondensing