Digital trigger, Vxibus trigger, Power requirement – National Instruments VXI-MIO Series User Manual

Page 110: Physical, Environment

Advertising
background image

Appendix A Specifications for VXI-MIO-64XE-10

VXI-MIO Series User Manual

A-16

National Instruments Corporation

External input (PFI0/TRIG1)

Impedance .................................. 10 k

Coupling ..................................... DC

Protection ................................... -0.5 to 5.5 V when configured as

a digital signal;

±

35 V when configured as an

analog trigger signal or disabled;

±

35 V powered off

Accuracy............................................

±

1% of fullscale range

Digital Trigger

Compatibility .....................................TTL

Response............................................Rising or falling edge

Pulse width ........................................10 ns min

VXIbus Trigger

Trigger lines.......................................Supports 5 TTL and 2 ECL

trigger lines

Power Requirement

+5 VDC .............................................2.82 A typ; 3.38 A max*

(*Not including current used by
accessories.)

-5.2 VDC ...........................................0.15 A typ; 0.18 A max

-2 VDC ..............................................0.04 A typ; 0.06 A max

Power available at I/O connector .......+4.65 VDC to +5.25 VDC

at 1 A

Physical

Dimensions .......................................VXI C-size single slot

I/O connector .....................................96-pin DIN

Environment

Operating temperature........................0 to 55

°

C

Storage temperature ...........................-20 to 70

°

C

Relative humidity...............................5% to 90% noncondensing

Advertising