Chapter 3 Hardware Overview

National Instruments Corporation

3-17

VXI-MIO Series User Manual

VXIbus Triggers

The VXI-MIO Series modules can use up to seven of the 10 VXIbus

trigger lines to coordinate sampling and/or triggering across multiple
modules.

When using NI-DAQ software, the VXIbus trigger lines are

functionally equivalent to RTSI bus trigger lines.

Figure 3-10. VXIbus Trigger Utilization

Refer to the Timing Connections section of Chapter 4 for a description

of the signals shown in Figure 3-10.

VXIbus Trigger Lines

Crossbar Switch

TTL Triggers

5

ECL Triggers

2

DAQ-STC

TRIG1

TRIG2

CONVERT*

UPDATE*

WFTRIG

GPCTR0_SOURCE

GPCTR0_GATE

GPCTR0_OUT

STARTSCAN

AIGATE

SISOURCE

UISOURCE

GPCTR1_SOURCE

GPCTR1_GATE

RTSI_OSC (20 MHz)