Chapter 2 Configuration and Installation

VXI-MIO Series User Manual

2-6

National Instruments Corporation

accessible with the cover on. To access the SIMM sockets, perform the
following steps:

1.

Remove the four screws on the top, the four screws on the bottom,

and the three screws on the right-side cover of the metal enclosure.

2.

If the SIMMs are 4 MB x 32 bit or larger, set S3 as shown in

Figure 2-4a.

3.

For SIMMs smaller than 4 MB x 32 bit, set S3 as shown in

Figure 2-4b.

Figure 2-4.

SIMM Size Configuration

Refer to Table 2-1 to properly adjust the switch (ON or OFF) for all

supported DRAM configurations. Many of the DRAM options are
available from National Instruments.

Table 2-1.

VXI-MIO Series DRAM Configuration

Bank 0

Bank 1

Total

DRAM

National

Instruments Option

Switch Setting

of S3

0

256 KB x 32 bit or
256 KB x 36 bit

1 MB

ON

256 KB x 32 bit or
256 KB x 36 bit

256 KB x 32 bit or
256 KB x 36 bit

2 MB

ON

512 KB x 32 bit or
512 KB x 36 bit

2 MB

ON

512 KB x 32 bit or
512 KB x 36 bit

512 KB x 32 bit or
512 KB x 36 bit

4 MB

ON

SIMM Size

(Factory Default)

SIMM Size

(Factory Default)

S3

S3

a. 4 MB X 32 bit or larger

b. Smaller than 4 MB X 32 bit