Chapter 4 Signal Connections

National Instruments Corporation

4-21

VXI-MIO Series User Manual

external reference input to be used by that channel. If you do not specify
an external reference, the channel will use the internal reference.

You

cannot use an external analog output reference with the
VXI-MIO-64XE-10.

Analog output configuration options are explained

in the

Analog Output

section in Chapter 3,

Hardware Overview

. The

following ranges and ratings apply to the EXTREF input signal:

Usable input voltage range:

±

11 V peak with respect to AOGND

Absolute maximum ratings:

±

15 V peak with respect to AOGND

AOGND is the ground reference signal for both analog output channels

and the external reference signal.

Figure 4-8 shows how to make analog output connections and the

external reference input connection to your VXI-MIO Series module.

Figure 4-8.

Analog Output Connections

The external reference signal can be either a DC or an AC signal. The

module multiplies this reference signal by the DAC code (divided by
the full-scale DAC code) to generate the output voltage.

+

-

+

-

+

-

Channel 0

Channel 1

External

Reference

Signal

(Optional)

Load

Load

V

OUT

0

V

OUT

1

DAC1OUT

AOGND

DAC0OUT

EXTREF

Analog Output Channels