NEC VisuaLink 128/384 User Manual

Page 56

Advertising
background image

Page 4-28

NDA-24230 Issue 2.0

Chapter 4

VisuaLink 128/384 User Guide

Optional information:

You may enter this optional information. The name you enter makes it easy for
users to identify this particular VisuaLink. The name can be up to 20 characters
long. The Password is the password needed to be entered when selecting the
Utilities ICON. After entering the optional information select the NEXT to
advance to the next screen.

Application Screen’s

Using the number pad on the wireless remote controller select the application
which the VisuaLink is installed. Your answer to this question will automatically
configure the internal parameters for the following:

Step 1- Optional User Settings

Your Site Name
[ ]

Password [ ]

Time Setting
[12/1/1998 10:50]
Time Display: <Time only>

Auto Power Save: <OFF>

Next screen
Prior screen

Press ENTER after choosing each item

Item

Rollabout/Other

Data Conference

Gateway

Desktop

Serial Port 1

Camera EVI-D30

T.120

Camera

Camera

Serial Port 2

Console

Console

Console

Console

Audio Mode

G.722

G.728

G.722

G.722

MLP

4.0

24.0

4.0

4.0

Answer Mode

Auto

Auto

Auto

Manual

LSD

1.2

Off

1.2

1.2

Ext. Remote

Auto

Off

Off

Off

H.263

Off

Off

Off

Off

Lip Sync

On

On

On

On

Advertising