Remote Maintenance by Telnet (mshell)

67

5

The following example shows how set the protocol for an address.

msh> snmp

number {ip | ipx} address

Note

❒ When using the TCP/IP protocol, input ip followed by a space and then

the IP address.

❒ When using the IPX/SPX protocol, input ipx followed by a space and then

the IPX address followed by a decimal and then the MAC address of the
Network Interface Board.

The following is an example of how to configure registration number 3 with
the IP address 192.168.15.16.

msh> snmp 3 ip 192.168.15.16

The following is an example of how to configure registration number 3 with
the IPX address 7390A448, and the MAC address 00:00:74:62:5C:65.

msh> snmp 3 ipx 7390A448.000074625C65

Changing the Password

Use the passwd command to change the remote maintenance password.

Important

❒ Be sure not to forget or lose the password.

Note

❒ The default factory password is “password”.

A

Input “passwd”.

msh> passwd

B

Input the current password.

Old password:

C

Input the new password.

New password:

Note

❒ The password must consist of 3 to 8 alphanumeric characters and symbols.

Upper and lower case characters are considered unique. For example, R is
different from r.

❒ The password is the same as that used in the configuration of the Network

Interface Board using a Web browser and that used in the NIB Setup Tool.
If you change a password on the mshell, the other passwords are also
changed.

D

Input the new password once again.

Retype new password: