Memory sets

With the factory settings, the GM2 set shown in the illustration is assigned to the controllers.
Use the included template.
The following memory sets are also provided.

GM2 set (MEMORY: 0)

.................................... (p. 100)

MCR-8 MODE 3 (SONAR 2) SET

.................. (p. 101)

MCR-8 MODE 3 (SONAR 2) - A (MEMORY: 1).... (p. 101)
MCR-8 MODE 3 (SONAR 2) - B (MEMORY: 2)
.... (p. 101)
MCR-8 MODE 3 (SONAR 2) - C (MEMORY: 3)
.... (p. 101)
MCR-8 MODE 3 (SONAR 2) - D (MEMORY: 4).... (p. 101)

MCR-8 MODE 4 (Cubase 5/SX) SET

............ (p. 102)

MCR-8 MODE 4 (Cubase 5/SX) - A (MEMORY: 5)(p. 102)
MCR-8 MODE 4 (Cubase 5/SX) - B (MEMORY: 6)(p. 102)
MCR-8 MODE 4 (Cubase 5/SX) - C (MEMORY: 7))(p. 102)
MCR-8 MODE 4 (Cubase 5/SX) - D (MEMORY: 8)(p. 102)

H-COMPATIBLE (ProTools LE, Digital Performer 3)

SET (MEMORY: 9)

.................................................. (p. 103)

GS SET

..................................................................... (p. 103)

GS-A (MEMORY: A) .......................................................(p. 103)
GS-B (MEMORY: B).........................................................(p. 104)
GS-C (MEMORY: C)
........................................................(p. 104)

XG SET

..................................................................... (p. 105)

XG-A (MEMORY: D).......................................................(p. 105)
XG-B (MEMORY: E)
........................................................(p. 105)

For details on settings for actually using each memory set with your application, refer to the Read Me file for
each memory set, located in the Memory Files folder of the CD-ROM.

Since the PCR-1 does not have controllers [P1] and [P2], the PCR-1 itself is unable to transmit or edit the
messages assigned to these controllers.
(Internally, the PCR-1 does maintain data for [P1] and [P2].)
In order to maintain memory set compatibility with other models in the PCR series, all memory sets include
the data for [P1] and [P2] when they are bulk-dumped.

GM2 set (MEMORY: 0)

Parameter

Message (Hex.)

Range (Hex.)

Ch.

Port

R1

FILTER CUTOFF

CC 74(4A)

0(00) - 127(7F)

1

1

R2

FILTER RESONANCE

CC 71(47)

0(00) - 127(7F)

1

1

R3

VIBRATO RATE

CC 76(4C)

0(00) - 127(7F)

1

1

R4

VIBRATO DEPTH

CC 77(4D)

0(00) - 127(7F)

1

1

R5

VIBRATO DELAY

CC 78(4E)

0(00) - 127(7F)

1

1

R6

COARSE TUNING

RPN 0/2(00/02)

0/-(00/–) - 127/-(7F/–)

1

1

R7

FINE TUNING

RPN 0/1(00/01)

0/0(00/00) - 127/127(7F/7F)

1

1

R8

PAN (CHANNEL)

CC 10(0A)

0(00) - 127(7F)

1

1

S1

PORTAMENTO TIME

CC 5(05)

0(00) - 127(7F)

1

1

S2

AFTERTOUCH

CHANNEL PRESSURE

0(00) - 127(7F)

1

1

S3

ENVELOPE ATTACK

CC 73(49)

0(00) - 127(7F)

1

1

S4

ENVELOPE DECAY

CC 75(4B)

0(00) - 127(7F)

1

1

S5

ENVELOPE RELEASE

CC 72(48)

0(00) - 127(7F)

1

1

S6

CHORUS

CC 93(5D)

0(00) - 127(7F)

1

1

S7

REVERB

CC 91(5B)

0(00) - 127(7F)

1

1

S8

VOLUME (CHANNEL)

CC 7(07)

0(00) - 127(7F)

1

1

B1

PROGRAM CHANGE DEC PROGRAM CHANGE

min:1(00)

-

-

B2

PROGRAM CHANGE INC

PROGRAM CHANGE

max:128(7F)

-

-

B3

PORTAMENTO ON/OFF

CC 65(41)

0(00) / 127(7F)

1

1

B4

POLY MODE ON

B0 7F 00

-

1

1

B5

MONO MODE ON

B0 7E 01

-

1

1

B6

GM2 SYSTEM ON

F0 7E 7F 09 03 F7

-

-

1

L1

STOP

FC

-

-

2

L2

START

FA

-

-

2

L3

CONTINUE

FB

-

-

2

P1

HOLD

CC 64(40)

0(00) / 127(7F)

1

1

P2

EXPRESSION

CC 11(0B)

0(00) - 127(7F)

1

1