Use MIDI functionality

RPN / NRPN ASSIGN

Here’s how you can assign an RPN or NRPN message to a controller.

fig.edt2

1

Press the

[EDIT]

button.

The display will indicate “EDT”.

fig.r-1

2

Slightly move the controller to which you want to assign an RPN or NRPN
message. In the case of a button, press that button.

The display will indicate the number of the selected controller.

3

Confirm what’s indicated, and press the

[ENTER]

button.

fig.rp0

4

Press an

ASSIGNABLE FUNCTION

key (

) on the keyboard enough times

to get "RP0" to appear in the display.

fig.np0

* If you want to assign an NRPN message, press the

[NRPN]

key. The following procedure

is the same as for RPN.

fig.c

5

Confirm what’s indicated, and press the

[ENTER]

button.

The display will blink “C–”.

6

Input the channel. Use the

[DEC] [INC]

buttons or the

[0]

[F]

keys to specify the channel.

7

Press the

[ENTER]

button.

fig.BANK-2

8

Use the

[DEC] [INC]

buttons or the

[0]

[F]

keys to specify the RPN MSB

(CC#101) or NRPN MSB (CC#99).

Mode

Keyboard

Data entry MSB

(CC#6) range

Data entry LSB

(CC#38) range

Port

Basic mode

0

0-127 (00–7FH)

Not transmitted

PORT 1

Advanced mode 1

1

Assignable

0-127 (00–7FH)

Assignable

*1 Reference

*1 Reference

*1 The -- area displays the currently set value. If it has not been set, the default setting will be displayed. Even if you change the type or mode

of the MIDI message that is assigned, the default setting will be displayed. This will be lit if the value is the same as the currently set value,

or will blink if the value is different.