Bulk dump, System exclusive message, Universal non-realtime system exclusive – Roland PCR-1 User Manual

Page 119: Data transmission

Advertising
background image

119

MIDI implementation

System exclusive message

The PCR-1 is able to transmit the following exclusive messages: exclusive messages
assigned to the controllers, Identity Reply, and Bulk Dump.

Universal non-realtime system exclusive

Identity reply

This message will be transmitted when an Identity Request message is received.

Status

Data byte

Status

F0H

7EH,10H,06H,02H,41H,62H,01H,

F7H

00H,00H,02H,01H,00H,00H

Byte

Explanation

F0H

Exclusive status

7EH

ID number (Universal non-realtime message)

10H

Device ID (For the PCR-1, fixed at 10H)

06H

Sub ID #1 (General Information)

02H

Sub ID #1 (Identity Reply)

41H

ID number (Roland)

62H 01H

Device family code

00H 00H

Device family number code

02H 01H

Software revision level

00H 00H

:

F7H

EOX (End of Exclusive)

Data transmission

Data Set 1 DT1 (12H)

Transmitted when you execute Bulk TX in the Bulk mode.
Status

Data byte

Status

F0H

41H, 10H, 00H, 62H, 12H,
aaH, ddH, ...eeH, sum

F7H

Byte

Explanation

F0H

Exclusive status

41H

ID number (Roland)

10H

Device ID

00H

Model ID #1 (PCR-1)

62H

Model ID #1 (PCR-1)

12H

Command ID (RQ1)

aaH

Address

ddH

Data

:
:
:
eeH

Data

sum

Checksum

F7H

EOX (End of Exclusive)

*

The amount of data that can be transmitted at once is fixed for each type of data.
Data that does not have the specified starting address and data size will not be
received. Refer to the explanation in 3. Bulk Dump.

*

There must be an interval of at least 40 ms between each exclusive message that
is sent.

*

Also, you must leave an interval of at least 500 ms after transmitting one set of
bulk dump data.

3. Bulk dump

Bulk dump allows a large amount of data to be transferred in a single operation.
For example, this can be used to store all settings of a device into a computer or
sequencer.
On the PCR-1, a bulk dump will be transmitted when you execute the Bulk mode
operation BULK TX. The bulk dump is transmitted as several exclusive messages.

Address

Parameter

Packets

00H, 00H, 00H, 00H--00H, 00H, 1A, 7FCurrent memory

27

*

You must leave an interval of at least 40 ms between each exclusive message.

*

In the case of ALL BULK, the contents of memories 1--F will be transmitted as
the current memory, consecutively from memory 1 through memory F. After
transmitting one set of bulk dump data, you must leave an interval of at least
500 ms.

*

Please be aware that if you modify the data dumped from the PCR-1 by
changing the order in which the exclusive messages are transmitted, by
inserting other messages between the system exclusive messages, or by
speeding up the timing of the transmission, the data may not be set correctly
when the PCR-1 receives it.