Specifying the location of the data, P. 80) – Roland PCR-1 User Manual

Page 80

Advertising
background image

80

Use MIDI functionality

Specifying the location of the data

Here’s how to specify the location and data type of the variable portion (data) within a system
exclusive message.
The range of data values will be the default range in the case of Basic mode or Advanced mode
3. In the case of Advanced modes 1 and 4, you can specify the range of data values.
For an actual example, please read the Sys Ex. ASSIGN section

Master Volume

(p. 83).

1.

Press the

[DATA]

key at the location where you want to input the data.

The display will indicate “DT0”.

2.

Use the

[0]

[4]

keys to select the type of data.

* In the case of DT1–DT4 (data consisting of two or more bytes), a data area will automatically be allocated

for the next byte, and “-DT” will be displayed. (This cannot be changed.)

3.

Press the

[ENTER]

button.

4.

If you selected DT1 through DT4, the display will indicate “-DT”.
Press the

[ENTER]

button.

Data

number

Data type

Default range

Target of range setting

Example

(specified upper/lower limits)

DT0

7bit

00H–7F

Specify the range of data
(00H–7FH)

04–45
(lower limit 4H, upper limit 45H)

DT1

4bit/4bit

0H/0H–FH/FH

Specify the range of the first byte (0H–FH),
second byte is fixed at 0H–FH

0/0–D/F
(lower limit 0H, upper limit DH)

DT2

7bit/7bit
(MSB/LSB)

00H/00H–7FH/
7FH

Specify the MSB range (00H–7FH), LSB is
fixed at 00H–7FH

23/00–68/7F
(lower limit 23H, upper limit 68H)

DT3

7bit/7bit
(LSB/MSB)

00H/00H–7FH/
7FH

Specify the MSB range (00H–7FH), LSB is
fixed at 00H–7FH

00/23–7F/68
(lower limit 23H, upper limit 68H)

DT4

4bit/4bit/
4bit/4bit

7H/FH/0H/1H–
8H/0H/FH/FH

Specify the limits of positive/negative
change as a value from 00H to FFH, cen-
tered on 8000H.

7/F/0/2–8/0/5/0
(lower limit FEH, upper limit 50H)

8000H

FF

FF

max

min

PCR-1_e1.book 80 ページ 2003年11月20日 木曜日 午後3時22分