1 setting ip and control preferences – Omnitron Systems Technology iConverter 10/100M User Manual

Page 13

Advertising
background image

3.4.1

Setting IP and Control Preferences

An IP address is required for the SNMP manager to address the 10/100M. The factory default setting is
192.168.1.220. The IP address can be configured manually or automatically as a DHCP client.

3.4.1.1

Setting IP Parameters Manually

To manually configure the IP address and control parameters, select 3 from the Management Options
screen. The IP and Control Preferences screen will appear.

IP and Control Preferences Screen

iConverter, Serial Agent

1: Set IP

192.168.1.220

2: Set Subnet Mask

255.255.255.0

3: Set Gateway

192.168.1.1

4: Chassis Number

1

5: Chassis Name (also sysName)

10/100M

6: Enable/Disable TELNET

Enabled

7: Enable/Disable FTP

Disabled

8: Enable/Disable Soft Switch Reload

Disabled

9: TELNET Password

*****

10: FTP Password

11: Serial Password

Enter Choice, Management Options Screen(0), (H)elp, E(x)it >

To configure the IP address of the 10/100M, select 1 at the IP and Control Preferences screen, and press
<ENTER>. Backspace over the existing value, type the new value (in x.x.x.x format), and press <ENTER>.

To configure the subnet mask of the 10/100M, select 2 at the IP and Control Preferences screen, and press
<ENTER>. Backspace over the existing value, type the new value (in x.x.x.x format), and press <ENTER>.

To configure the gateway of the 10/100M, select 3 at the IP and Control Preferences screen, and press
<ENTER>. Backspace over the existing value, type the new value (in x.x.x.x format), and press <ENTER>.

To save the new values, select 0 and press <ENTER> to return to the Management Options screen, then
select 6 and press <ENTER> to Save Preference Changes.

3.4.1.2

Setting IP Parameters as DHCP Client

To configure the IP automatically as a DHCP client, select 9 from the Management Options screen. The
Other Networking Features screen will appear.

Page 13

Advertising