2 configuring dip-switches, 1 board-mounted bank 1 settings, Configuring dip-switches – Omnitron Systems Technology iConverter 10/100M User Manual

Page 6: Board-mounted bank 1 settings

Advertising
background image

3.2

CONFIGURING DIP-SWITCHES

The 10/100M plug-in module has two board-mounted DIP-switches. The standalone unit has one bank of
DIP-switches. The locations of the DIP-switches are illustrated below.

DIP-switch Locations

3.2.1

Board-Mounted Bank 1 Settings

DIP-switch Bank 1 is available on both the plug-in and standalone modules. The table indicates the position
of the switch; Left/Down or Right/Up. As indicated in the DIP-switch location diagram, Left and Right
refers to the plug-in module and Down and Up refers to the standalone module.

(Left/Right)

(Up/Down)

Switch

Left/Down

(Factory Default)

Right/Up

SW1

Off:
Pause Disable

On:
Pause Enable

SW2

FDX:
Fiber Full-Duplex

HDX:
Fiber Half-Duplex

SW3

AN:
UTP Auto-Negotiate

Man:
UTP Manual

SW4

100:
UTP 100Mbps

10:
UTP 10Mbps

SW5

FDX:
UTP Full-Duplex

HDX:
UTP Half-Duplex

SW6 - SW8

See Link Mode DIP-Switch Table in Section 3.2.1.6

3.2.1.1

SW1 - Pause Disable/Enable “Off/On”

When a port is operating in auto-negotiation, its Pause operation mode is determined by the Pause capability
advertised during auto-negotiation between itself and the link partner. The port advertises its Pause capability
during auto-negotiation based on the Pause Disable/Enable DIP-switch setting. Setting the Pause DIP-switch to

Page 6