Possible Causes:

A. Confirm that the UTP cable is connected properly to the iConverter 10/100M and the attached UTP
device. Once a connection has been established between the iConverter and its link partner (switch or
workstation), the UTP “10/100” LED should illuminate. If the LED does not illuminate, check the Link
Mode configuration. A link mode other than Link Segment may cause the UTP “10/100” LED not to turn
ON.

B. Verify the iConverter 10/100M UTP port is configured with the proper settings based on the attached
device (AN or MAN, 10 or 100, HD or FD).

C. Verify the distance between the iConverter and the link partner is within 100 meters.

D. Confirm that the UTP cable pin-out is correct (EIA/TIA-568-A). The module has auto-crossover
capability, so it will accept either a straight-through or crossover cable.

NOTE: If corrective actions do not resolve your situation, please contact Omnitron Systems Technical
Support.