When the upload is complete, the 10/100M displays the update status and then automatically restarts with
the newly loaded firmware.

3.4.5.4

Updating the 10/100M Firmware via FTP

Using an FTP application, upload the new firmware into the FTP root directory of the 10/100M. When the
file transfer is complete, the 10/100M verifies the file and then automatically restarts with the newly loaded
firmware.

For detailed instructions on updating the management modules and other modules in the same chassis via
FTP, download the application note “iConverter Management: Updating Modules via FTP” available on
Omnitron’s web page:

http://www.omnitron-systems.com/downloads.php

See Setting 10/100M Passwords Section 3.4.1.4, on how to configure FTP.

3.5

VERIFY OPERATION

Once the module has been installed and configured, per Sections 3.2 - 3.4, verify the module is operational
by viewing the status of the LED indicators. The table below provides a description for each LED indicator.

The Power LED indicates the module is receiving power from the chassis or power cord. The plug-in
modules has an LED indicator for each available power supply in the chassis (the 19-Module Chassis has
three, the 5-Module Chassis has two).

The Fiber Optic “FO” LED indicates the fiber optic connection between the modules has been established.
A blinking LED indicates the presence of data.

The UTP “10/100” LED indicates the module has established a connection across its UTP port. A blinking
LED indicates the presence of data.

Refer to Section 6.0, Troubleshooting Guide, for help in determining possible fault conditions.

LED Function

"Legend"

Color

Off State

On / Blinking State

On / Blinking State

Power "Pwr"

Amber No power

On: Module has power

On: Module has power

Power Supply
Status #X

Amber

Chassis Power
Supply not installed

On: Power available from
installed Power Supply #X
Blinking: No power available

from installed Power Supply #X

Not available on standalone

100Mbps Fiber

Optics "FO"

Green No Fiber Link

On: Fiber link is active
Blinking: Fiber Data Activity

On: Fiber link is active
Blinking: Fiber Data Activity

Chassis
Management
Master/Slave
"BP"

Green

Chassis Slave
Mode

On: Chassis Master Mode
Blinking: Operating in OAM
Mode

Not available on standalone

UTP port

10Mbps "10"

Green 10Mbps not active

On: 10Mbps UTP link is active
Blinking: UTP Data Activity

On: 10Mbps UTP link is active
Blinking: UTP Data Activity

UTP port

100Mbps "100"

Green 100Mbps not active

On: 100Mbps UTP link is active
Blinking: UTP Data Activity

On: 100Mbps UTP link is active
Blinking: UTP Data Activity

UTP port Full-
Duplex "FDX"

Green

Half-Duplex when
any UTP link is
active

Full-Duplex when any UTP link
is active

Full-Duplex when any UTP link
is active

Note: On some models the fiber optic LED is referred to as ‘P1’.