12 installation – Omni Group GREEN SMART 864 User Manual

Page 12

Advertising
background image

12 Installation

(for qualified installers only)

© Travis Industries

4090507

100-01217_000

Minimum Framing Dimensions – Top or Side Vent Configuration

* The 23" (584mm) dimension is based upon 1/2" (13mm)
drywall around the perimeter of the fireplace on both sides. If
using thicker drywall (or other facing), you will need to adjust this
dimension.

44"

1118mm

Minimum 42”(1067mm)

Fireplace Enclosure Height

NOTE:

The shaded framing must be

installed after placing the fireplace

in position.

The framing above the fireplace
interferes with the top of the fireplace.
If using the side vent configuration, do
not install the framing to the left side
(shown in light gray).

38-1/2"
978mm

23" *
584mm

Back

Front

Right

Left