58 optional equipment, Extra room power heat duct, For qualified installers only) – Omni Group GREEN SMART 864 User Manual

Page 58: Special instructions for 864 st, Power heat duct wiring diagram, Remove the heat shield cover plate

Advertising
background image

58 Optional

Equipment

(for qualified installers only)

© Travis Industries

4090507

100-01217_000

Extra Room Power Heat Duct

SKU 98500769

Special Instructions for 864 ST

The 864 ST has a removable cover plate shield below the heat duct connections. This allows more heat

to be routed to the power heat ducts (see below for details). Otherwise the heat duct is installed the

same as an 864TRV (one heat duct kit maximum, manually-controlled on/off operation – see wiring

diagram below).

Power Heat Duct Wiring Diagram

Power Heat Duct Wiring Diagram

• 864 TRV

• 864 ST

• 864 HH

(sn 3407-001009 or less)

Hot

(black)

Common

(white)

Ground

(green)

Power Supply

Hot

(black)

Common

(white)

Ground

(green)

Rheostat

Junction Box

Blower

Assembly

-Remove the Heat Shield Cover Plate

Remove and discard the power heat
duct cover plate.

Remove and discard the circular cover
plate attached to the heat shield.

NOTE

: an additional power heat

duct hook-up location is provided
on the right side (it is along the top
edge of the fireplace).

NOTE

: Only one hook-up may be

used (do not hook up two heat
ducts to the fireplace).