Side Vent Configuration with Vertical Termination

The termination must fall

within the shaded area

shown in the chart. Use

the indicated restrictor

and diffuser positions.

Up to four elbows (45°

or 90°) may be used.

Only one horizontal

elbow may be used.

5 feet (1.5m)

0 feet

0 feet

5 feet (1.5m)

0 feet

20 feet (6m)

20 feet (6m)

5 feet (1.5m)

10 feet (3m)

5 feet (1.5m)

10 feet (3m)

0 feet

15 feet (4.5m)

20' max (6m)

10 feet (3m)

15 feet (4.5m)

15 feet (4.5m)

20' max (6m)

10 feet (3m)

15 feet (4.5m)

40' max (12m)

Exhaust Restrictor # 4
Intake Restrictor # 2
Diffuser Position # 1

25 feet (7.5m)

30 feet (9m)

35 feet (10.5m)

40' max (12m)

25 feet (7.5m)

30 feet (9m)

35 feet (10.5m)

Exhaust Restrictor # 2
Intake Restrictor # 1
Diffuser Position # 1

This is considered a horizontal
elbow (it does not matter

whether it turns right or left).
It may be a 90° or 45° elbow.

This is considered a
vertical elbow

Horizontal length is calculated by adding

both lengths of horizontal run
(Horizontal Length = H1 + H2).

H1

H2